Objective:
3D printing and extrusion-based technologies, especially semi-solid extrusion (SSE), are promising solutions to fulfil the need to personalize pediatric medicines. In this study an automated SSE based Compounding System Solution (CSS) technology was assessed for creating customized Ondansetron tablets. Additionally, a non-destructive quality control method for the customized Ondansetron tablets was developed by utilizing Raman Spectroscopy (RS) measurements and partial least square (PLS) analysis.
Methods:
Tablets of 400 mg with varying Ondansetron content (2-10 mg) and different sizes (200-500 mg) with 0.5% Ondansetron were manufactured and tested according to European and US Pharmacopoeia standards, HPLC, and the RS-based PLS model.
Results:
The mass uniformity tests showed high accuracy: 99.2% for varying drug content and 98.8% for different tablet sizes. All tablets met the acceptance criteria (AV < 15) and remained stable for six months at 25 ± 2 °C and ambient humidity. In-vitro dissolution tests confirmed over 85% drug release within 30 min, complying with USP standards. The RS-based PLS model predicted active pharmaceutical ingredient (API) content with a slope of 0.944 and an error of ~ 8%, which improved to 2-3% when excluding highly variable 10 mg samples. The model showed strong correlation with HPLC results and prediction (R2CV = 0.95, RMSECV = 0.68; R2Pred = 0.96, RMSEP = 0.57), using three latent variables.
Conclusion:
In conclusion, the CSS technology, validated through pharmacopoeia tests, HPLC, and RS, effectively produces high-quality, personalized Ondansetron tablets. The study demonstrates the feasibility of using SSE and RS-based quality control for individualized pediatric drug formulations.
Related Concept Videos
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
Factors Influencing Drug Absorption: Pharmaceutical Parameters
Raman Spectroscopy: Overview
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and...