Related Experiment Video
Updated: Sep 8, 2025

Excitation-Scanning Hyperspectral Imaging Microscopy to Efficiently Discriminate Fluorescence Signals
Published on: August 22, 2019
Indocyanine green excitation-emission matrix characterization: excitation-dependent emission shifts and
Alberto J Ruiz1, Sophie A Lyon1, Ethan P M LaRochelle1
1QUEL Imaging, White River Junction, VT, USA.
Significance:
Indocyanine green (ICG) is the most widely used fluorophore in fluorescence-guided surgery (FGS), yet its spectral response depends on microenvironment, with implications for system design, inter-system comparisons, and phantom development.
Aim:
To characterize ICG with excitation-emission matrices (EEMs) in the microenvironments of dimethyl sulfoxide (DMSO), bovine serum albumin (BSA) solutions, and 3D-printed (3DP) resin, and assess excitation-dependent emission, including red-edge excitation shifts (REES) and departures from Kasha's rule of excitation-independent emission.
Approach:
EEMs and absorbance spectra were acquired with extracted excitation spectra, emission spectra, emission peaks, centroids, and integrated emission areas under the curve (AUCs). Concentration-dependent behavior was examined in DMSO, and albumin concentration dependence was assessed from 5-100 mg/mL. Data processing employed robust local regression to mitigate excitation scattering artifacts.
Results:
ICG in DMSO exhibited excitation-independent emission consistent with Kasha-Vavilov behavior. In contrast, ICG in BSA solution and 3DP resin displayed excitation-dependent emission with pronounced REES and additional non-linear departures from Kasha's rule. To our knowledge, this represents the first documentation of REES and broader anti-Kasha effects for ICG or any FGS fluorophore. Within the excitation range most relevant to ICG-FGS (~760-805 nm), emission spectra of the BSA solution and 3DP resin overlapped closely, with similar AUC-based comparisons, suggesting that ICG in 3DP resin can serve as a suitable surrogate reference for albumin-bound ICG.
Conclusions:
The EEM characterization shows that excitation-dependent behavior is a defining feature of ICG in biologically relevant environments, demonstrating that emission cannot be assumed to follow classical Kasha-Vavilov behavior. Reliable comparisons and imaging system design therefore require spectra acquired at defined excitation wavelengths with AUC integration within the emission detection band. Excitation-specific spectra from EEMs establish a consistent framework for inter-system comparisons and phantom standards, while the resulting datasets provide a practical reference for addressing excitation-dependent behavior in ICG sensing applications.
More Related Videos
05:14Author Spotlight: Overcoming Anti-VEGF Resistance Through Advanced Vascular Morphology Assessment in Choroidal Neovascularization
Published on: August 11, 2023
07:24Hyperspectral Imaging as a Tool to Study Optical Anisotropy in Lanthanide-Based Molecular Single Crystals
Published on: April 14, 2020
Related Concept Videos
Molecular Spectroscopy: Absorption and Emission
UV–Vis Spectroscopy: Molecular Electronic Transitions
UV–Vis Spectroscopy of Conjugated Systems
One of the factors influencing λmax is the extent...
IR Spectroscopy: Molecular Vibration Overview
Stretching vibrations are vibrational motions that occur along the bond line, changing the bond length or distance between two bonded atoms. They are further distinguished as symmetric or asymmetric. In symmetric stretching, the...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
Applications of IR Spectroscopy: Overview