Fabric-Based Flexible Pressure Sensor Arrays with Ultra-Wide Pressure Range for Lower Limb Motion Capture System
Xiaohua Wu1, Yuxuan Liang1, Longsheng Lu1
1School of Mechanical & Automotive Engineering, South China University of Technology, Guangzhou 510641, China.
None:
The lower limb motion capture technology has garnered significant attention as a pivotal enabler in extended reality, sports science, film production, and medical rehabilitation. However, existing mature systems face critical challenges, including restricted operational environments, interference with natural activities, and cumbersome wearability. Here, a flexible insole pressure sensor array with an ultra-wide sensing range is developed using dip coating, laser cutting, and hot pressing, enabling lower limb motion capture. The developed fabric-based flexible pressure sensor exhibited an ultra-wide pressure range (3,770.9 kPa), high sensitivity (2.68 kPa-1), rapid response, recovery times (17.2 ms/3.5 ms), and high work life (>4 million loading/unloading cycles). The insole-shaped flexible pressure sensor array accurately measures pressure in different postures, achieving 95.5% classification accuracy across 10 dynamic and static poses. More importantly, the system achieved a joint position prediction accuracy of 7.8 pixels (~3.6 cm) in lower limb pose estimation. This high-precision lower limb motion capture system represents an ideal terminal for future extended reality applications, offering seamless integration, comfortable use, easily wearable design, and broad accessibility.
Related Concept Videos
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessing Blood pressure in the Leg
Preparation:
Pressure Gauges
Measurement of Blood Pressure
Measurement of Fluid Pressure
A basic form of manometer is the piezometer, a vertical tube open at the top and filled with the same...