Related Experiment Video
Updated: Sep 10, 2025

Assessing the Accuracy of Fitness Smartwatch Data for Cardiovascular and Physical Activity Monitoring: A Validation Study in Digital Health
Published on: February 21, 2025
Validation of nocturnal resting heart rate and heart rate variability in consumer wearables
Michael B Dial1,2, Margaret E Hollander1,2, Emaly A Vatne1
1Human Performance Collaborative, Office of Research, The Ohio State University, Columbus, Ohio, USA.
Abstract:
Modern wearable devices report several heart rate-based nocturnal health metrics, including resting heart rate (RHR) and heart rate variability (HRV). The purpose of this study was to assess the validity of nocturnal RHR and HRV from five wearable devices (Garmin Fenix 6, Oura Generation 3, Oura Generation 4, Polar Grit X Pro, & Whoop 4.0) against an electrocardiogram (ECG) reference. Thirteen healthy adults (6 females) wore an ECG reference and multiple wearables simultaneously during sleep, totaling 536 nights. Interdevice accuracy varied significantly (p < 0.05). For RHR, Oura Gen 3 (Lin's Concordance [CCC] = 0.97, mean absolute percentage error [MAPE] = 1.67 ± 1.54%) and Gen 4 (CCC = 0.98, MAPE = 1.94 ± 2.51%) demonstrated the highest accuracy, outperforming Polar's poor (CCC = 0.86, MAPE = 2.71 ± 2.75%) and WHOOP's moderate agreement (CCC = 0.91, MAPE = 3.00 ± 2.15%). Garmin was excluded from RHR analyses due to methodological inconsistencies. For HRV, Oura devices provided the highest accuracy; Oura Gen 4 (CCC = 0.99, MAPE = 5.96 ± 5.12%), Oura Gen 3 (CCC = 0.97, MAPE = 7.15 ± 5.48%). WHOOP showed moderate accuracy (CCC = 0.94, MAPE = 8.17 ± 10.49%), followed by poor agreement from both Garmin (CCC = 0.87, MAPE = 10.52 ± 8.63%) and Polar (CCC = 0.82, MAPE = 16.32 ± 24.39%). Oura devices showed the highest agreement for RHR and HRV, and WHOOP showed acceptable agreement, whereas Garmin Fenix and Polar demonstrated lower concordance, highlighting the importance of continuous validation and providing valuable benchmarks for clinicians, researchers, and consumers.
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Holter Monitor: 24-Hour Monitoring
Factors Influencing Heart Rate
Let us explore the significant factors affecting heart rate, including age, body temperature, posture, acute pain, chemical influences,...
Regulation of Heart Rates
The SNS increases heart rate through the release of norepinephrine and epinephrine, which act on beta-1 adrenergic receptors in the heart. This action increases the rate of depolarization in the sinoatrial (SA) node, the heart's...
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Special considerations while measuring pulse