Considerations for the Validation of Non-CFU Based Bio-Fluorescent Particle Counting Technologies
Cynthia Martindale1, Caroline Dreyer2, Cedric Joossen3
1Applied Rapid Microbiology Specialists, Ltd., USA.
PDA Journal of Pharmaceutical Science and Technology
|August 20, 2025
Summary
Bio-Fluorescent Particle Counting (BFPC) offers a rapid, non-growth-based alternative for microbial monitoring. This paper provides validation recommendations for BFPC technology in pharmaceutical applications.
Area of Science:
- Microbiology
- Analytical Chemistry
- Pharmaceutical Science
Background:
- Bio-Fluorescent Particle Counting (BFPC) is an emerging non-growth-based technology for microbial detection.
- Pharmaceutical industry interest in BFPC for water and cleanroom air monitoring is growing.
- BFPC methods report results in units other than colony-forming units (CFUs), posing validation challenges.
Purpose of the Study:
- To provide recommendations for validating non-growth-based BFPC technologies.
- To address challenges in validating alternative microbial methods compared to traditional growth-based methods.
- To offer guidance for the pharmaceutical industry on BFPC method validation pathways.
Main Methods:
- The Modern Microbial Methods (M³ ) industry working group collaborated to develop recommendations.
- Focus on technology-specific primary and secondary validation strategies for BFPC.
- Consideration of validation parameters and acceptance criteria applicable to non-CFU reporting methods.
Main Results:
- The study outlines a method validation pathway tailored for BFPC technology.
- Specific recommendations are provided for primary and secondary validation stages.
- Discussion on adapting validation parameters for a technology that does not rely on colony formation.
Conclusions:
- BFPC technology presents a viable alternative for microbial monitoring in pharmaceutical settings.
- Standardized validation approaches are crucial for the successful implementation of BFPC.
- The recommendations aim to facilitate the adoption and regulatory acceptance of BFPC methods.
Related Concept Videos
Flow Cytometry
The development of flow cytometry techniques began in 1934 with initial attempts by Andrew Moldavan, a bacteriologist who counted the cells in a flowing capillary system. Moldavan pumped cells through a capillary tube focused under a microscope for visualization. The invention of photometry allowed the measurement of differentially-stained cells, and Louis Kamentsky developed the first multiparameter flow cytometer in 1965 to identify and count the cancer cells in cervical tissue specimens.
In...
In...
Microbial Growth Measurement: Direct Methods
Direct methods for measuring microbial populations in a culture are essential tools in microbiology, providing quantitative data for various applications. Among these, microscopic counts, plate counts, and serial dilution are widely used techniques, each with unique principles and applications.Microscopic CountsMicroscopic counting involves the use of a Petroff-Hausser chamber, a specialized microscope slide with a grid and defined depth. By observing a liquid culture under a microscope,...
Methods to Assess Microbial Populations
Assessing microbial populations is crucial for understanding microbial roles in health, ecology, and industry. Various complementary techniques—both culture-based and molecular—enable detailed analysis of microbial abundance, diversity, and function.Viable Plate CountThe viable plate count is a traditional culture-based method used to estimate the number of living microbes in a sample. After serial dilution, the sample is spread onto nutrient agar plates. Each viable cell forms a visible...