Parameter analysis using swallowing sounds shows differences in bolus volume, bolus viscosity, sex, and age
Yuka Konoike1,2, Kei Naramura3, Takahiro Hasegawa3
1Department of Nutritional Science, Okayama Prefectural University, 111 Kuboki, Soja, 719-1197, Okayama, Japan.
Abstract:
Acoustic analysis of pharyngeal sounds during swallowing may capture physiological functions, providing a noninvasive method for early screening of swallowing decline. In this study, we examined changes in swallowing function across variations in bolus volume, bolus viscosity, sex, and age using parameters such as swallowing duration, average voltage, and swallowing power derived from swallowing sounds. The results showed that average voltage and swallowing power were significantly higher in men, both in younger (aged 20-25 years) and older (aged 50-65 years) groups, regardless of bolus volume and viscosity. These parameters generally decreased as bolus viscosity increased, with significant differences observed in all participants except older men. Regarding swallowing duration, older men took significantly longer to swallow a high-viscosity bolus compared to younger men, whereas no age-related differences were observed in women. This finding suggests that men experience greater age-related deterioration in swallowing than women. Overall, this simple and noninvasive measurement method appears to be an effective and objective tool for evaluating swallowing function. It is capable of detecting alterations associated with sex and aging, as well as changes in swallowing status related to the physical properties of dysphagia diets.
Related Concept Videos
Two-Compartment Open Model: IV Bolus Administration
The disparity between drug input and the sum of drug transfer rates between...
One-Compartment Open Model for IV Bolus Administration: Estimation of Clearance
In the one-compartment open model for intravenous (IV) bolus administration, clearance is estimated by dividing the elimination rate by the plasma drug concentration. This equation leverages the elimination rate constant and the apparent...
One-Compartment Open Model for IV Bolus Administration: General Considerations
The drug's presence in the body is defined by an equation representing the difference between the rates of drug entry and exit. Key parameters—elimination rate constant,...
One-Compartment Open Model for IV Bolus Administration: Estimation of Elimination Rate Constant, Half-Life and Volume of Distribution