Comparison of Dosimetry Models and Dose Thresholds for Predicting Pathologic Response to Yttrium-90 Radioembolization
Kurt T Pianka1, Mark Barahman2, Jeet Minocha2
1School of Medicine, University of California San Diego, La Jolla, CA, USA.
Purpose:
This study evaluated pathologic response to ablative transarterial radioembolization (TARE) and compared single-compartment, mean tumor dose, and voxel-based dosimetry thresholds for hepatocellular carcinoma (HCC).
Materials And Methods:
This is a retrospective, single-center study which included consecutive patients treated with glass microsphere TARE for a previously untreated HCC followed by liver transplantation between January 2015 - December 2024. A complete response (CR) was assigned if explant pathology showed complete pathologic necrosis (CPN) and if the patient had not undergone further treatments to the tumor. The standard single-compartment, dual-compartment mean tumor, and voxel-based doses were compared for patients with CR and without.
Results:
Of the forty-three patients included, 29 had a CR. The only single-compartment dose threshold significantly associated with CR was ≥ 400 Gy, with a positive predictive value (PPV) of 77%. Mean tumor dose thresholds of ≥ 300 and ≥ 400 Gy were associated with CR (PPV 75 and 76%, respectively). The highest PPV for CR observed was for the voxel-based dose threshold of D95 ≥ 500 Gy, at 88%. Single-compartment, dual-compartment mean tumor, and D95 doses were all significantly associated with the likelihood of CR in separate multivariable logistic regression analyses. The incidence of AEs did not vary significantly based on the tested dose thresholds.
Conclusion:
Increasing the single- and dual-compartment dose thresholds beyond ≥ 400 Gy did not result in significant associations with CR nor improved PPV. In contrast, D95 ≥ 500 Gy was significantly associated with CR with the highest observed PPV.
Level Of Evidence:
Level 3, Local Non-random Sample.
More Related Videos
07:57Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
Published on: March 24, 2022
09:11Y-90 Radioembolization and PD-1 Inhibitor as Neoadjuvant Treatment in Hepatocellular Carcinoma
Published on: May 24, 2024
Related Concept Videos
Compartment Models: Two-Compartment Model
One-Compartment Open Model for IV Bolus Administration: Estimation of Elimination Rate Constant, Half-Life and Volume of Distribution
Pharmacokinetic Models: Comparison and Selection Criterion
Physiological models take a detailed approach by considering specific molecular processes. They can predict drug distribution, metabolism, and elimination changes, providing a comprehensive understanding of how drugs interact with the body.
Dosage Regimen Designs: Nomograms and Tabulations
Pharmacodynamic Models: Direct Effect Model and Indirect Response Model
Impact of Pharmacokinetic–Pharmacodynamic Models: Regulatory Decisions