Cork-based electrochemical sensors obtained by laser-induced graphene: A green alternative for sodium nitrite
Beatriz F Germinare1, Wilson S Fernandes-Junior2, Jéssica R Camargo1
1Laboratory of Sensors, Nanomedicine, and Nanostructured Materials, Federal University of São Carlos, Araras, São Paulo, 13604-900, Brazil.
Abstract:
A laser-pyrolyzed cork-based electrochemical sensor is proposed for the determination of sodium nitrite, a widely used food additive that poses potential health risks. The pyrolysis parameters were varied individually, and electrochemical performance was compared to select the conditions that provided the highest conductivity and sensitivity. Additionally, a chemical treatment with a waterproofing spray was applied to enhance sensor stability and ensure reproducible measurements. The proposed sensor was characterized by scanning electron microscopy (SEM), X-ray energy dispersive spectroscopy (EDS), attenuated total reflectance Fourier-transform infrared spectroscopy (ATR-FTIR), Raman spectroscopy, X-ray diffraction (XRD), and thermogravimetric analysis (TGA). The performance of the sensor was evaluated for sodium nitrite detection in different beverage samples, including wine, orange juice, and mineral water. The results demonstrated a linear response range from 300 to 1000 μmol L⁻1, with a limit of detection of 14.4 μmol L⁻1. Recovery tests indicated satisfactory accuracy, with values ranging from 86.1% to 110.8%, confirming the method's applicability to real samples. The results of this study reinforce the potential of cork as a sustainable substrate for high-performance electrochemical sensors, a viable and promising alternative for food analysis, replacing less eco-friendly conventional substrates.
More Related Videos
11:18Manufacturing of a Nafion-coated, Reduced Graphene Oxide/Polyaniline Chemiresistive Sensor to Monitor pH in Real-time During Microbial Fermentation
Published on: January 7, 2019
07:51Development and Functionalization of Electrolyte-Gated Graphene Field-Effect Transistor for Biomarker Detection
Published on: February 1, 2022
Related Concept Videos
Potentiometry: Membrane Electrodes
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a result, EDTA...
Microbial Biosensors