Agreement of Automated Oscillometric Blood Pressure Measurement Device with the Manual Mercury Sphygmomanometer
Sana Ahmed1, Yamini Gusain1, Renuka Pathak1
1Institute of Home Economics, University of Delhi, New Delhi, India.
Abstract:
The usage of the manual mercury sphygmomanometer to measure blood pressure (BP) is universally regarded as the gold standard, but its use has decreased globally due to concerns about potential mercury toxicity. Automated BP devices have become more popular, though their accuracy in detecting hypertension hasn't been studied extensively. This cross-sectional study was conducted on 301 adult female students of the University of Delhi with the aim to assess the degree of agreement between standard manual mercury sphygmomanometer and automated BP monitor (Omron JPN1). Three consecutive BP readings were taken on the left arm by a certified medical doctor using both instruments. Bland Altman plots were created to assess the degree of agreement between the two BP devices and to test the accuracy of automated BP monitor in detecting hypertensive adults. The automated BP monitor underestimated the systolic BP measurement by 4 mmHg and diastolic BP measurement by 7 mmHg as determined by Bland Altman plot. Based on international validation protocols, a mean difference of < 5 ± 8 mmHg was established to assess the level of agreement between the two devices. The automatic BP monitor did not show complete agreement with the "gold standard" mercury sphygmomanometer. With growing restrictions on the use of mercury sphygmomanometers, its replacement with an equivalent mercury-free validated device is urgently needed.
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Assessment of blood pressure in brachial artery(two-step method)
Measurement of Blood Pressure
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.