Selective Detection of Carbon-Centered Radicals in Water via a Fluorescent Probe and High-Resolution Mass

Jihong Xu1, Yong Huang1, Lin Li1

  • 1Shanghai Engineering Research Center of Biotransformation of Organic Solid Waste, Institute of Eco-Chongming, School of Ecological and Environmental Sciences, East China Normal University, Shanghai 200241, China.

PubMed

Related Concept Videos

Gas Chromatography: Types of Detectors-II01:19

Gas Chromatography: Types of Detectors-II

In gas chromatography, different detectors are employed to meet specific analytical needs. These detectors are often categorized based on their detection mechanisms and the types of compounds they are best suited to analyze. Thermal Conductivity Detectors (TCD), Flame Ionization Detectors (FID), and Electron Capture Detectors (ECD) represent common categories, each with unique operating principles and applications. However, beyond these, several other detectors are designed for more specialized...
498
Electron Paramagnetic Resonance (EPR) Spectroscopy: Organic Radicals01:17

Electron Paramagnetic Resonance (EPR) Spectroscopy: Organic Radicals

Ideally, an unpaired electron shows a single peak in the EPR spectrum due to the transition between the two spin energy states. However, coupling interactions can occur between the spins of the unpaired electron and any neighboring spin-active nuclei. This hyperfine coupling results in hyperfine splitting, where the EPR signal is split into multiplets. The signals split into 2nI + 1 peaks, where n is the number of equivalent nuclei and I is the nuclear spin. These splitting patterns provide...
2.7K
High-Resolution Mass Spectrometry (HRMS)01:15

High-Resolution Mass Spectrometry (HRMS)

The resolution of a mass spectrometer depends on the efficiency of separating ions with different ion masses. The mass of an atom is approximated to the sum of the masses of protons and neutrons inside, considering the masses of protons and neutrons as equal. However, the masses of the proton (1.6726 × 10−24 g) and neutron (1.6749 × 10−24 g) are not truly equal. There is a minor error in the expression of atomic masses relative to the simplest atom of hydrogen. For...
1.6K
High-Performance Liquid Chromatography: Types of Detectors01:15

High-Performance Liquid Chromatography: Types of Detectors

The role of the detectors in High-Performance Liquid Chromatography (HPLC) is to analyze the solutes as they exit from the chromatographic column. The detector recognizes the solute's property and generates corresponding electrical signals, which are converted into a readable graph of the detector's response versus elution time called a chromatogram at the computer. There are several types of HPLC detectors, each with its own advantages and limitations, depending on the analyte...
791
Mass Spectrometry: Branched Alkane Fragmentation01:29

Mass Spectrometry: Branched Alkane Fragmentation

This lesson delves into the mass spectrometry of branched alkane fragmentation. Branched alkanes possess secondary or tertiary carbon atoms, which generate relatively stable carbocations if the cleavage occurs at the branching point. The high stability of carbocations drives the instant fragmentation of branched alkanes. Accordingly, the branched alkane's molecular ion peak is very weak or invisible in the mass spectra, especially in comparison to a linear alkane.
1.1K
Radicals: Electronic Structure and Geometry01:07

Radicals: Electronic Structure and Geometry

This lesson delves into the geometry of a radical, which is influenced by the electronic structure of the molecule. The principle is similar to that of a lone pair, where the unpaired electron influences the geometry at the radical center.
Accordingly, the structure of a trivalent radical lies between the geometries of carbocations and carbanions. An sp2-hybridized carbocation is trigonal planar, while an sp3-hybridized carbanion is trigonal pyramidal. Here, the difference in geometry is...
4.2K