Related Experiment Video
Updated: Sep 10, 2025

Proton Therapy Delivery and Its Clinical Application in Select Solid Tumor Malignancies
Published on: February 6, 2019
Carbon ion radiotherapy optimization techniques for pancreatic cancer: accounting for the effect of bowel gas
Chaebeom Sheen1, Sunghyun Lee2,3,4,5, Bitbyeol Kim2,3
1Seoul National University College of Medicine, 101 Daehak-ro, Jongno-gu, Seoul, 03080, Korea (Republic of).
Background:
Dose variation due to changes in bowel air poses significant challenges for carbon radiotherapy in pancreatic cancer. This retrospective study evaluated a density-override optimization technique to mitigate dosimetric uncertainties caused by bowel air changes.
Materials And Methods:
Planning CT and cone-beam CT data from 8 patients with locally advanced pancreatic cancer undergoing stereotactic ablative radiotherapy were analyzed. Treatment simulations used a dose of 55.2 GyE in 12 fractions with a four-field setup (anterior, lateral, posterior, posterior oblique). Four density-override patterns were compared: pattern 0 (no override), pattern 1 (replacing bowel gas with water), pattern 2 (replacing the entire bowel with mean bowel HU), and pattern 3 (replacing bowel gas with mean bowel HU). Dose evaluations included fraction-wise and accumulated dose analyses, focusing on target coverage, homogeneity index, and organs at risk doses.
Results:
Pattern 2 achieved the largest clinical tumor volume coverage and the fewest fractions with > 5% coverage loss for the anterior beam, followed by pattern 3. However, pattern 2 demonstrated poorer homogeneity for the lateral beam compared to patterns 1 and 3 and a higher gastrointestinal (GI) dose for the anterior beam.
Conclusion:
This study evaluated the importance of density overrides to address bowel air variations. For patients where a more uniform dose is desirable or whose tumor is adjacent to the GI tract, a pattern 3 density-override should be considered.
More Related Videos
08:54Treatment of Liver Metastases Using an Internal Target Volume Method for Stereotactic Body Radiotherapy
Published on: May 8, 2018
07:57Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
Published on: March 24, 2022
Related Concept Videos
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and...