Related Experiment Video
Updated: Sep 10, 2025

Scattering And Absorption of Light in Planetary Regoliths
Published on: July 1, 2019
Effects of inter-crystal scattering events on the performance of SIAT aPET
Zhonghua Kuang1,2, Ling Zhang1, Ning Ren2
1Microelectronics and Optoelectronics Technology Key Laboratory of Hunan Higher Education, School of Physics and Electronic Electrical Engineering, Xiangnan University, Chenzhou 423000, People's Republic of China.
Abstract:
Objective.The probability of 511 keVγ-rays undergoing inter-crystal scattering (ICS) in current positron emission tomography (PET) detectors is high. The objective of this research is to study the impact of the ICS events on the performance of the small animal SIAT aPET scanner.Approach.The SIAT aPET scanner is composed of 48 detectors organized in 4 rings with each ring containing 12 detectors. Each detector is composed of a 23 × 23 crystal array dual-ended read out by two 8 × 8 silicon photomultiplier arrays with resistor network circuits. In this work, a specific method was proposed to identify the single interaction (non-ICS) and ICS events (both interactions are undergoing ICS). A point source, two hot rod phantoms and a NEMA image quality (IQ) phantom were scanned and images were reconstructed using different types of events.Main results.The average full width at half maximum spatial resolutions of the point source obtained with all, non-ICS and ICS events are 0.62 mm, 0.52 mm, and 0.97 mm, respectively. The 1.0 mm diameter rods can be clearly resolved from the images of the ultra-micro hot rod phantom obtained with both all events and only the non-ICS events, but the image obtained with the non-ICS events show a 40% better peak-to-valley ratio for the 1.0 mm rods. The 1.35 mm rods can be clearly resolved from the image obtained with the ICS events. The images of the NEMA IQ phantom showed that the contrast recovery coefficients for hot rods with 1-5 mm diameters were improved by 24% in average, but the signal-to-noise ratio of the uniform region was decreased by 46% with the rejection of the ICS events (at least oneγ-ray undergoing ICS).Significance.The results of this work provide useful guidance on whether it is necessary to use detectors that are capable of identifying the ICS events for PET scanners of different spatial resolution.
Related Concept Videos
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
X-ray Crystallography
Diffraction
Diffraction is the change in the direction of travel experienced by an electromagnetic wave when it encounters a physical barrier whose dimensions are comparable to those of the wavelength of the light. X-rays are electromagnetic radiation with wavelengths about as long as the distance between neighboring...