Related Experiment Video
Updated: Sep 10, 2025

Assessing Hepatic Metabolic Changes During Progressive Colonization of Germ-free Mouse by 1H NMR Spectroscopy
Published on: December 15, 2011
Targeted mass spectrometry method for the determination of multiple gut-microbiota metabolites in human plasma
Sara R Fernandes1, Cristian Azorín2, Eduarda M P Silva3
1LAQV, REQUIMTE, Department of Chemical Sciences, Faculty of Pharmacy, University of Porto, Rua de Jorge Viterbo Ferreira 228, 4050-313 Porto, Portugal; ESS, Polytechnic of Porto, Rua Dr. António Bernardino de Almeida 400, 4200-072 Porto, Portugal.
Abstract:
The gut microbiota profoundly impacts human health by producing metabolites that can act as biomarkers for disease diagnosis and therapy. However, accurately measuring these metabolites in biomatrices is challenging due to their low concentrations, high molecular diversity, and interference from matrix components, demanding advanced and precise analytical methodologies. Hence, an ultra-high-performance liquid chromatography method coupled to triple quadrupole-tandem mass spectrometry detection, combined with a chemical derivatization procedure, was developed and validated to quantify seven gut metabolites, namely acetic acid, propionic acid, butyric acid, p-cresol sulfate, 3-indoxyl sulfate, indole-3-acetic acid, and L-tryptophan, in human plasma. Samples were prepared by protein precipitation with acetonitrile and subsequently derivatized using 3-nitrophenylhydrazine. Chromatographic separation was achieved using a BEH C18 column, with elution performed at a flow rate of 0.2mLmin-1 and in gradient mode using formic acid-water (1:1000, v/v) and formic acid-acetonitrile (1:1000, v/v) as mobile phase components. The mass spectrometer was operated in negative ionization mode and data was acquired in selected reaction monitoring. Good linearity was achieved (r2 > 0.997) for all the target gut metabolites in the evaluated concentration ranges, with low LLOQ values (0.4-8 μM). The method proved to be accurate (87.0-114 %) and precise (CV ≤ 13.5 %), achieving a score of 65 in the Blue Applicability Grade Index (BAGI) metric, which confirmed its practicality. The developed method was ultimately employed to the analysis of plasma samples from children and adults involved in clinical studies, demonstrating its usefulness in medical research.
More Related Videos
11:00Untargeted Metabolomics from Biological Sources Using Ultraperformance Liquid Chromatography-High Resolution Mass Spectrometry UPLC-HRMS
Published on: May 20, 2013
07:34Large Scale Non-targeted Metabolomic Profiling of Serum by Ultra Performance Liquid Chromatography-Mass Spectrometry UPLC-MS
Published on: March 14, 2013