Related Experiment Video
Updated: Sep 10, 2025

MRM Microcoil Performance Calibration and Usage Demonstrated on Medicago truncatula Roots at 22 T
Published on: January 16, 2021
A concentric-loops coil enhancing RF coil B1 efficiency and reducing imaging noise compared to traditional
Xin Li1, Xiao-Hong Zhu1, Wei Chen1
1Center for Magnetic Resonance Research, Department of Radiology, University of Minnesota, Minneapolis, MN, USA.
None:
We proposed a simple approach to optimize a concentric-loops RF coil, consisting of an inner primary coil as the driving coil and an outer secondary coil as a passive resonator. By adjusting the tuning capacitor in the secondary loop to raise its self-resonance frequency to be slightly above the operating Larmor frequency, we enabled the preferred operation condition (additive mode), where both secondary and primary loops contributed to the largely enhanced RF coil transmit and receive magnetic fields (B1) within the area enclosed by the primary loop as compared to a single-loop secondary coil. Compared to a single secondary loop coil as control, electromagnetic (EM) simulations and phantom MRS/MRI at 10.5 Tesla (T) 17O (60.6 MHz), 7 T 31P (120.7 MHz), and 1.5 T 1H (63.8 MHz) operating frequencies show that the concentric-loops coil (8 cm diameter for the secondary loop coil) provides 1.2 to 1.4-fold higher B1 and coil detection sensitivity in the near-coil region (0-3 cm). In the far region, it offers slightly enhanced B1 and coil sensitivity, which becomes similar to the control coil at 9 cm away from the coil plane. Additionally, the concentric-loops coil reduces imaging noise by 15-30 %, collectively, resulting in an ∼1.7-fold signal-to-noise ratio (SNR) gain at the near-coil region. The concentric-loops coil with the presented optimization strategy provides an effective and simple coil design with largely improved imaging SNR compared to a conventional single-loop coil for a broad range of MRS/MRI applications across different field strengths.
Related Concept Videos
Magnetic Field Of A Current Loop
Torque On A Current Loop In A Magnetic Field
Consider a rectangular current-carrying loop containing N turns of wire, placed in a uniform magnetic field. The net force on a current-carrying loop...
NMR Spectrometers: Resolution and Error Correction
Force On A Current Loop In A Magnetic Field
Mutual Inductance
When two circuits carrying time-varying currents are close to one another, the magnetic flux through each circuit varies because of the changing current in the other circuit. Consequently, an emf is induced in each circuit by the changing current in the other. Therefore, this type of emf is called...
Magnetic Field Due To A Thin Straight Wire