Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Electrical Energy01:10

Electrical Energy

Using electric appliances for a longer period of time consumes more electrical energy and results in a higher electric bill. The energy produced by the transfer of electrons from one point to another is known as electrical energy. If power is delivered at a constant rate, the electrical energy can be defined as the product of power used by the device for a period of time. The energy unit on electric bills is the kilowatt-hour, where one kilowatt-hour is equivalent to 3.6 × 106 joules. The...
Biasing of P-N Junction01:16

Biasing of P-N Junction

The operation of a p-n junction diode involves various biasing conditions, including forward bias, reverse bias, and equilibrium.
In equilibrium, no external voltage is applied across the p-n junction. The depletion region is formed at the junction interface due to the diffusion of carriers, which leaves behind charged dopants, acceptors on the p-side, and donors on the n-side. These immobile charges create an electric field that prevents further diffusion of carriers. The related energy band...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Effect of an oxygen-releasing mouthwash on <i>Aggregatibacter actinomycetemcomitans</i> and HaCaT cells: A pilot study.

Journal of Indian Society of Periodontology·2026
Same author

A Pilot Study on the Evaluation of Hetafu Mouthwash in Oral Biofilm of Orthodontic Patients: A Clinical Trial.

Cureus·2026
Same author

Blue®m gel vs hyaluronic acid gel in wound healing and pain control following functional crown lengthening: a randomized controlled trial.

The Saudi dental journal·2026
Same author

Blastic plasmacytoid dendritic cell neoplasm: A single centre Indian experience.

Leukemia research reports·2026
Same author

Intravenous Fosaprepitant Versus Oral Aprepitant for Children Receiving Highly Emetogenic Chemotherapy: An Investigator-Initiated Randomized, Open-Label, Non-Inferiority Trial.

Pediatric blood & cancer·2026
Same author

Anatomical Risk Factors Associated with Inferior Alveolar Nerve Injury During Third Molar Surgery: A Systematic Review.

Journal of maxillofacial and oral surgery·2026

Related Experiment Video

Updated: Jun 18, 2026

An In Vitro Approach to Photodynamic Therapy
04:53

An In Vitro Approach to Photodynamic Therapy

Published on: August 17, 2018

8.8K

Heat Generated by Different Light-Emitting Diode (LED) Curing Units and Their Effect on Pulp: An In Vitro Study.

Santhosh Kumar1, Jithesh Kumar2, Panjami Marish2

  • 1Department of Orthodontics, Adhiparasakthi Dental College and Hospital, Chennai, IND.

Cureus
|August 25, 2025
PubMed
Summary

Higher intensity LED curing lights, like Woodpecker, can increase pulp chamber heat during orthodontic bonding, potentially causing mild inflammation. These thermal effects appear mostly reversible, but sustained rises may irritate dental pulp.

Keywords:
histopathologic diagnosisled curing lightsorthodontic bondingpulpal inflammationthermal effects

More Related Videos

Rose Bengal-Mediated Photodynamic Therapy to Inhibit Candida albicans
04:48

Rose Bengal-Mediated Photodynamic Therapy to Inhibit Candida albicans

Published on: March 24, 2022

3.3K
LED-Based In Vitro Screening for Assessing Photoactivable Molecules in Bacterial Photodynamic Inactivation
05:13

LED-Based In Vitro Screening for Assessing Photoactivable Molecules in Bacterial Photodynamic Inactivation

Published on: January 24, 2025

453

Related Experiment Videos

Last Updated: Jun 18, 2026

An In Vitro Approach to Photodynamic Therapy
04:53

An In Vitro Approach to Photodynamic Therapy

Published on: August 17, 2018

8.8K
Rose Bengal-Mediated Photodynamic Therapy to Inhibit Candida albicans
04:48

Rose Bengal-Mediated Photodynamic Therapy to Inhibit Candida albicans

Published on: March 24, 2022

3.3K
LED-Based In Vitro Screening for Assessing Photoactivable Molecules in Bacterial Photodynamic Inactivation
05:13

LED-Based In Vitro Screening for Assessing Photoactivable Molecules in Bacterial Photodynamic Inactivation

Published on: January 24, 2025

453

Area of Science:

  • Dentistry
  • Biomaterials Science
  • Orthodontics

Background:

  • Light-emitting diode (LED) curing units in orthodontics can cause thermal changes in the pulp chamber.
  • Excessive heat may lead to pulpal inflammation or damage, varying by curing light type and power.
  • Understanding these thermal effects is crucial for preventing iatrogenic pulpal injury.

Purpose of the Study:

  • To quantify heat generation by different LED curing lights during orthodontic bonding.
  • To evaluate the resulting histopathological changes in pulpal tissue.
  • To correlate light intensity with thermal effects and pulpal response.

Main Methods:

  • 42 human premolars were used, divided into histological and thermal assessment groups.
  • Temperature changes in the pulp chamber were measured using thermocouples before and after curing.
  • Histopathological evaluation assessed pulpal inflammation; statistical analyses included chi-square and ANOVA.

Main Results:

  • The Woodpecker LED unit (Group B) showed mild to moderate pulpal inflammation (p=0.047).
  • Group E (Woodpecker thermal) had the highest temperature rise (2.586°C), though not statistically significant between groups (p=0.064).
  • Significant variations in pre- and post-curing temperatures were noted across devices (p<0.011), with 3M Unitek showing higher values.

Conclusions:

  • Higher intensity LED curing lights, specifically the Woodpecker unit, generated more heat, potentially causing early pulpal inflammation.
  • Observed pulpal changes were largely reversible.
  • A sustained temperature increase exceeding 5.5°C could be a threshold for pulpal irritation.