Related Experiment Video
Updated: Sep 10, 2025

Manufacturing Simple and Inexpensive Soil Surface Temperature and Gravimetric Water Content Sensors
Published on: December 21, 2019
Study on the Effects of Temperature Asynchrony on the Accuracy of Electrical Resistance Probes
Yuanguang Yue1, Zhibiao Yin1, Shiming Li1
1National Engineering Laboratory of Advanced Coating Technology for Metal Materials, Central Iron & Steel Research Institute, Beijing 100081, China.
Abstract:
The precision of atmospheric probe data acquisition is vulnerable to temperature asynchrony, largely due to the fact that temperature fluctuations can alter sensor response times and measurement outcomes, resulting in asynchronous and biased data collection. To assess the performance of electrical resistance (ER) probes across different scenarios, we employed the ratio of the measured resistance to that of a reference sample as our evaluation metric. Through both theoretical analysis and targeted experiments simulating temperature deviations, we have shown that temperature perturbations can induce substantial variations in the resistance of the test material. More specifically, the discrepancy in the measured values due to temperature asynchrony escalates with the extent of the temperature fluctuation, whereas the impact of such asynchrony diminishes at higher temperatures. In practical settings, incorporating dual thermocouples within the probe for real-time data correction presents significant challenges. Consequently, this study proposes a method for postprocessing raw data, which involves detecting and substituting anomalous values, influenced by temperature, with the median value. This approach ensures that the processed data faithfully represent the typical variations and trends observed in the probe readings, effectively reducing the adverse effects of temperature asynchrony on the accuracy of data acquisition.
More Related Videos
Related Concept Videos
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...