Objectives:
This study aimed to investigate the optimal trigger threshold for the renal CT angiography (CTA) protocol with the bolus-tracking technique.
Methods:
This retrospective study included patients suspected of having renal diseases and candidate kidney transplant donors who underwent renal CTA from July 2019 to August 2021. Renal arterial (RA) phase scanning was initiated using either one of the following two trigger thresholds: 50 HU (50-HU group; n = 42) and 100 HU (100-HU group; n = 63). A radiologist measured CT attenuations of the vasculature and renal parenchyma on RA phase images. Two radiologists classified RA phase images into appropriate RA-, late RA-, or corticomedullary (CM)-timing. Unpaired t- and Fisher's exact tests were conducted to assess differences in the CT attenuations and the proportion of categorical classifications between the two groups.
Results:
Overall, 105 patients (mean age: 59.8 years; 60 men) were included. CT attenuations of the aorta and renal arteries were comparable between the two groups (P = 0.38-0.95). CT attenuations of the renal cortex and renal vein were higher in the 100-HU group than in the 50-HU group (P = 0.006-0.04). The proportion of the appropriate RA-timing was higher, whereas that of the CM-timing was lower in the 50-HU group than in the 100-HU group (appropriate RA-, late RA-, and CM-timing: 78.6% vs. 50.8%, 19.0% vs. 34.9%, and 2.4% vs. 14.3%; P = 0.01 for reviewer 1 and 64.3% vs. 27.0%, 33.3% vs. 63.5%, and 2.4% vs. 9.5%; P < 0.001 for reviewer 2, respectively).
Conclusion:
The trigger threshold of 50 HU provided a higher probability of obtaining appropriate RA-timing images than that of 100 HU in the renal CTA protocol with the bolus-tracking technique.
More Related Videos
10:21Continuous Blood Sampling in Small Animal Positron Emission Tomography/Computed Tomography Enables the Measurement of the Arterial Input Function
Published on: August 8, 2019
04:37Improved Home Blood Pressure Control by CT-guided Ozone-mediated Renal Denervation for Patients with Resistant Hypertension
Published on: June 6, 2025
Related Concept Videos
Imaging Studies VII: Vascular Imaging
Imaging Studies III: Computed Tomography
Imaging Studies for Cardiovascular System V: CT
Radiological Investigation I: X-ray and CT