Coordinate Mapping of Hyolaryngeal Mechanics in Swallowing
Published on: May 6, 2014
Intra- and inter-rater reliability of swallowing-related muscle assessments using ultrasound devices
Shota Ishino1, Motoomi Nagasaka2, Koki Kawamura2,3
1Department of Rehabilitation, National Center for Geriatrics and Gerontology, 7-430, Morioka, Obu, Aichi, 474-8511, Japan. s.ishino@ncgg.go.jp.
Purpose:
To evaluate the inter- and intra-assessor reliability of ultrasonographic assessment of swallowing-related muscle indices in healthy young adults.
Methods:
Three examiners conducted ultrasonographic evaluations on healthy young adults (n = 34, age: ≥ 20 years) examining the thickness and area of the geniohyoid muscle, anterior belly of the digastric muscle, tongue, and the mylohyoid, masseter, and depressor anguli oris muscles. To assess inter-rater reliability, each examiner evaluated each assessment item for one subject three times on the same day. Intra-rater reliability was assessed by rater No. 3 re-evaluating the participants 4-7 days after the initial measurement, using the retest method. Image analysis was conducted by a single examiner utilizing an ultrasonography measurement tool. Statistical analysis was performed using intraclass correlation coefficients (ICCs) for intra- and inter-rater reliability.
Results:
The study included 34 participants (male: 17, female: 17; age: 25 ± 2 years, body mass index: 20.3 ± 1.7 kg/m2). For intra-rater reliability for thickness of the geniohyoid muscle, ICC = 0.94 [95% CI (0.89, 0.97)], and ICC = 0.90 [95% CI (0.81, 0.93)] for the area of the anterior belly of the digastric muscle. For inter-rater reliability, ICC = 0.93 [95% CI (0.88, 0.96)] and 0.86 [95% CI (0.77, 0.92)] for the thickness of the geniohyoid muscle, and area of the anterior belly of the digastric muscle, respectively.
Conclusions:
The inter- and intra-assessor reliability of ultrasound assessments of swallowing-related indices in young healthy subjects was good, exhibiting particularly high accuracy for the geniohyoid muscle and the anterior belly of the digastric muscle.
More Related Videos
08:40Isokinetic Robotic Device to Improve Test-Retest and Inter-Rater Reliability for Stretch Reflex Measurements in Stroke Patients with Spasticity
Published on: June 12, 2019
09:02Cortical Bone Assessment Using Ultrasonic Guided Waves: A Reproducibility Study in a Healthy Population
Published on: January 31, 2025
Related Concept Videos
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Ultrasound I: Abdominal Ultrasonography
Abdominal ultrasonography, commonly known as abdominal ultrasound, is a vital, non-invasive medical imaging technique widely used in healthcare.
Procedure:
This diagnostic tool allows the clinician to visually inspect internal structures within the abdomen, including vital organs such as the liver, gallbladder, pancreas, kidneys, and spleen.
The abdominal ultrasound process begins with applying a special gel to the patient's skin over the abdomen. This gel enhances the...
Ultrasonography
During an ultrasonography procedure, a handheld device called...