Related Experiment Video
Updated: May 2, 2026

The Development of Lyophilized Loop-mediated Isothermal Amplification Reagents for the Detection of Coxiella burnetii
Published on: April 18, 2016
A paper-based loop-mediated isothermal amplification assay coupled with a portable heating device for point-of-care
Krishnamoorthy Priya1, Ashish Kapoor2, Mohandass Ramya1
1Department of Genetic Engineering, School of Bioengineering, Faculty of Engineering & Technology, SRM Institute of Science and Technology, Kattankulathur, Tamil Nadu 603203, India. ramyam@srmist.edu.in.
Abstract:
Syphilis, a sexually transmitted disease caused by the spirochete bacterium Treponema pallidum, remains a significant global health concern. Serological methods are widely used but have limitations in early-stage infections and immunocompromised patients. This highlights the need for rapid, accurate, and cost-effective diagnostic tools to aid in syphilis management and outbreak prevention. Paper-based analytical devices have gained considerable attention in recent years for point-of-care applications due to their simplicity, low cost, and minimal equipment requirements. In this study, we have developed a paper-based loop-mediated isothermal amplification (LAMP) assay for the detection of T. pallidum DNA in clinical samples, targeting the Pol A and RNase P genes. The platform utilized a paper substrate integrated with hydroxy naphthol blue dye for visual colorimetric detection. A portable heating platform was designed to maintain the isothermal conditions necessary for amplification. The device demonstrated excellent stability when stored at 4 °C and 25 °C, with reproducibility significantly reduced at 37 °C. Sensitivity tests revealed a detection limit of 6.4 × 10-4 ng μL-1. Clinical evaluation of the paper-based LAMP assay was conducted using 52 suspected syphilis cases and 25 healthy volunteers. The assay achieved a sensitivity of 96.15% and a specificity of 100% in detecting syphilis. This portable, cost-effective device offers a promising lab-on-a-chip diagnostic solution for syphilis and can be adapted for detecting other infectious diseases.
More Related Videos
06:18Multiplexed Isothermal Amplification Based Diagnostic Platform to Detect Zika, Chikungunya, and Dengue 1
Published on: March 13, 2018
09:36Open-Source Miniature Fluorimeter to Monitor Real-Time Isothermal Nucleic Acid Amplification Reactions in Resource-Limited Settings
Published on: February 3, 2021
Related Concept Videos
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Types of Detectors-II
High-Performance Liquid Chromatography: Types of Detectors
Automated Microbial Diagnostics