Related Experiment Video
Updated: Sep 10, 2025

Optocardiography and Electrophysiology Studies of Ex Vivo Langendorff-perfused Hearts
Published on: November 7, 2019
A Phase 4, Open-Label, Non-Randomized, Multicenter Study to Evaluate Efficacy (and Safety) of Intravenous
Arash Sabati1, Shuo Wang2, Pushpa Shivaram3
1Division of Cardiology, Center for Heart Care, Phoenix Children's Hospital, 1919 E Thomas Road, Phoenix, AZ, 85016, USA. asabati@phoenixchildrens.com.
Abstract:
Contrast-enhanced echocardiography (CE-echo) is commonly used in adult patients to optimize endocardial border delineation (EBD) but there is limited experience in children. A prospective, open-label, non-randomized, multicenter study was performed to evaluate the efficacy of intravenous Optison for CE-echo in pediatric patients and determine the optimal dose of Optison. Subjects ≥ 9 and < 18 years with suboptimal echocardiograms (defined as ≥ 2 contiguous segments that could not be adequately visualized) were enrolled. After a baseline non-contrast echocardiogram (NC-echo), CE-echo was performed with 2 dose levels of Optison based on patient weight. The primary endpoint was visualization of the LV wall segments (LVWS) in apical 2- and 4-chamber views. An EBD score was calculated by assigning a value from 0 (no visualization) to 3 (optimal visualization) for 12 LVWS. 37 subjects across 8 sites completed the study. 30 had complete echocardiograms at both dose levels. 2 patients had usable images at dose 2 only. Mean age was 13.4 years (± 2.6) with 23 males (62%). Mean weight was 73.9 kg (± 36.8) with wide distribution of weight (interquartile range of 42-102 kg). There were 8 patients under 40 kg. Most subjects had a prior medical/surgical history (n = 33, 89%). Both dose levels of Optison CE-echo improved the number of LVWS visualized from 3.7 ± 1.1 on NC-echo to 10.0 ± 0.1 with dose 1 (p < 0.001) and 10.5 ± 0.1 with dose 2 (p < 0.001). EBD score also improved at both dose levels from 11.9 ± 2.5 for NC-echo to 28.5 ± 1.7 for dose 1 (p < 0.001) and 30.2 ± 8.4 for dose 2 (p < 0.001). The number of suboptimal echocardiograms improved from 92.3% ± 10.7 in NC-echo to 26.2% ± 9 with dose 1 (p < 0.001) and 30.8% ± 4.5 with dose 2 (p < 0.001). CE-echo with intravenous Optison in pediatric patients improved the number of LVWS visualized, improved EBD score, and reduced the number of suboptimal echocardiograms at both dosages used in this study. Intravenous Optison can improve LV visualization in pediatric patients with suboptimal echocardiograms.
Related Concept Videos
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for...
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion,...
Acute Kidney Injury IV: Diagnostic Studies and Prevention
Imaging Studies for Cardiovascular System V: CT
Imaging Studies III: Computed Tomography
Imaging Studies for Cardiovascular System IV: CMRI

