Related Experiment Video
Updated: May 6, 2026

Experimental Investigation of Secondary Flow Structures Downstream of a Model Type IV Stent Failure in a 180° Curved Artery Test Section
Published on: July 19, 2016
Development of a Computationally Efficient CFD Method for Blood Flow Analysis Following Flow Diverter Stent
Soichiro Fujimura1,2, Haruki Kanebayashi2,3, Kostadin Karagiozov4
1Department of Mechanical Engineering, Tokyo University of Science, Tokyo 125-8585, Japan.
None:
Intracranial aneurysms are a serious cerebrovascular condition with a risk of subarachnoid hemorrhage due to rupture, leading to high mortality and morbidity. Flow Diverter Stents (FDSs) have become an important endovascular treatment option for unruptured large or wide-neck aneurysms. Hemodynamic factors significantly influence treatment outcomes in aneurysms treated with FDSs, and Computational Fluid Dynamics (CFD) has been widely used to evaluate post-deployment flow characteristics. However, conventional wire-resolved CFD methods require extremely fine meshes to reconstruct individual FDS wires, resulting in prohibitively high computational costs. This severely limits their feasibility for use in clinical treatment planning, where fast and robust simulations are essential. To address this limitation, we developed a computationally efficient CFD method that incorporates a porous media model accounting for local variations in wire density after FDS deployment. Based on Virtual Stent Simulation, the FDS region was defined as a hollow cylindrical domain with spatially varying resistance derived from cell-specific wire density. We validated the proposed method using 15 clinical cases, demonstrating close agreement with conventional wire-resolved CFD results. Relative errors in key hemodynamic parameters, including velocity, shear rate, inflow rate, and turnover time, were within 5%, with correlation coefficients exceeding 0.98. The number of grid elements, the data size, and total analysis time were reduced by over 90%. The method also allowed comparison between Total-Filling (OKM Grade A) and Occlusion (Grade D) cases, and evaluation of different FDS sizing, positioning, and coil-assisted strategies. The proposed method enables practical and efficient CFD analysis following FDS treatment and supports hemodynamics-based treatment planning of aneurysms.
More Related Videos
09:57Development and Evaluation of 3D-Printed Cardiovascular Phantoms for Interventional Planning and Training
Published on: January 18, 2021
09:36A Magnetic Resonance Imaging-based Computational Protocol for Analysis of Plaque Morphology and Hemodynamics in Patients with Carotid Artery Stenosis
Published on: August 12, 2025
Related Concept Videos
Blood Flow
Flow Cytometry
In...
Applications of Integration to Find Blood Flow