Related Experiment Video
Updated: May 6, 2026

Engineering Platform and Experimental Protocol for Design and Evaluation of a Neurally-controlled Powered Transfemoral Prosthesis
Published on: July 22, 2014
Pain State Classification of Stiff Knee Joint Using Electromyogram for Robot-Based Post-Fracture Rehabilitation
Yang Zheng1,2, Dimao He1,2, Yuan He3
1School of Mechanical Engineering, Xi'an Jiaotong University, Xi'an 710049, China.
Abstract:
Knee joint stiffness occurs and severely limits its range of motion (ROM) after facture around the knee. During mobility training, knee joints need to be flexed to the maximum angle position (maxAP) that can induce pain at an appropriate level in order to pull apart intra-articular adhesive structures while avoiding secondary injuries. However, the maxAP varies with training and is mostly determined by the pain level of patients. In this study, the feasibility of utilizing electromyogram (EMG) activities to detect maxAP was investigated. Specifically, the maxAP detection was converted into a binary classification between pain level three of the numerical rating scales (pain) and below (painless) according to clinical requirements. Firstly, 12 post-fracture patients with knee joint stiffness participated in Experiment I, with a therapist performing routine mobility training and EMG signals being recorded from knee flexors and extensors. The results showed that the extracted EMG features were significantly different between the pain and painless states. Then, the maxAP estimation performance was tested on a knee rehabilitation robot in Experiment II, with another seven patients being involved. The support vector machine and random forest models were used to classify between pain and painless states and obtained a mean accuracy of 87.90% ± 4.55% and 89.10% ± 4.39%, respectively, leading to an average estimation bias of 6.5° ± 5.1° and 4.5° ± 3.5°. These results indicated that the pain-induced EMG can be used to accurately classify pain states for the maxAP estimation in post-fracture mobility training, which can potentially facilitate the application of robotic techniques in fracture rehabilitation.
More Related Videos
08:40Isokinetic Robotic Device to Improve Test-Retest and Inter-Rater Reliability for Stretch Reflex Measurements in Stroke Patients with Spasticity
Published on: June 12, 2019
05:25Author Spotlight: Assessing Brain Activity in Robotic-Assisted Lower Limb Rehabilitation Using fNIRS
Published on: June 7, 2024