A Novel Open-Loop Current Sensor Based on Multiple Spin Valve Sensors and Magnetic Shunt Effect with Position
Tianbin Xu1, Tian Lan1, Jiaye Yu1
1School of Electronics and Information, Hangzhou Dianzi University, Hangzhou 310018, China.
Abstract:
To address the demands for wide-range and high-precision current measurement, this paper proposes a novel current sensor design that integrates spin sensing technology, magnetic shunt effect, and a multi-sensor data fusion algorithm. The spin valve sensors accurately detect the magnetic field generated by the signal current, while the soft magnetic shunt structure attenuates the magnetic field to a level suitable for the spin valve sensors. Consequently, the detection current range can be extended by 6.8 times. Using four spin valve sensors and data fusion with an averaging algorithm, the system can calibrate the errors caused by the displacement or tilt of the current-carrying wire. Experimental results demonstrate that the current sensor achieves a sensitivity of 61.6 mV/V/A, an excellent linearity of 0.55%, and robust measurement performance, as well as strong anti-interference capability. Our study offers a novel solution for high-precision, wide-range current measurement in applications such as those in new energy vehicle electronics and precision electric energy metering.
More Related Videos
05:11High-precision Electromagnetic Flowmeter with Empty Pipe Detection via Complex Programmable Logic Device-based Waveform Recognition
Published on: June 27, 2025
10:52Design, Instrumentation and Usage Protocols for Distributed In Situ Thermal Hot Spots Monitoring in Electric Coils using FBG Sensor Multiplexing
Published on: March 8, 2020
Related Concept Videos
Galvanometer
The galvanometer consists of two concave-shaped permanent magnets, providing a uniform radial magnetic field in the annular region. In the center, a pivoted coil of fine copper wire is placed in the uniform...
Magnetic Field Of A Current Loop
Torque On A Current Loop In A Magnetic Field
Consider a rectangular current-carrying loop containing N turns of wire, placed in a uniform magnetic field. The net force on a current-carrying loop...
Magnetic Force Between Two Parallel Currents
The force exerted by the magnetic field due to the first conductor over a finite length of the second conductor is given as the product of the current in the second conductor and the vector product of the length vector along the current element and the field due to the first conductor. According to the...
Open and closed-loop control systems
An open-loop control system operates without feedback from the output. It consists of two primary elements: the controller and the controlled process. The controller receives an input signal...
Force On A Current Loop In A Magnetic Field