Abstract:
Heat exposure is an increasing threat to human health and accurately monitoring core body temperature is vital to avoiding heat-related illnesses during exercise and outdoor occupations. Recently, a wearable device (CORETM) was developed to non-invasively estimate core body temperature (TC). The purpose of this study was to determine the validity of the CORE sensor and identify subcutaneous fat as a potential contributor to the device's bias. Twenty-four healthy males (n = 13) and females (n = 11) completed 60 min of cycling exercise at 60 % of their maximum aerobic power output (166 ± 46.5 W) in the heat (35.9 °C & 20.7 % relative humidity). During exercise, TC and skin temperature (TSK) measures from the CORE sensor were compared to rectal probe and skin surface probe, respectively. Midaxillary subcutaneous fat thickness (MSFT) at the site of the CORE sensor was measured via ultrasonography. Throughout the entire exercise bout, the CORE displayed a non-statistically significant overestimation of TC (0.15 ± 0.43 °C, p = 0.057). However, CORE significantly overestimated TC during the third (0.31 ± 0.43 °C, p = 0.002) and fourth (0.36 ± 0.45 °C, p = 0.004) quarters of exercise. CORE also significantly overestimated TSK (1.28 ± 0.96 °C, p < 0.0001) throughout the entire exercise bout. MSFT was positively correlated with the bias in TC (overestimation by CORE) during the third (r = 0.438, p = 0.032) and fourth (r = 0.482, p = 0.017) quarters of exercise. In conclusion, compared to rectal temperature, the CORE sensor overestimated TC during constant-load exercise in a hot environment. Overestimated TSK and local subcutaneous fat may be potential contributors to bias in the CORE sensor's TC estimation.
More Related Videos
08:22Using an Ingestible Telemetric Temperature Pill to Assess Gastrointestinal Temperature During Exercise
Published on: October 7, 2015
05:51Assessing the Accuracy of Fitness Smartwatch Data for Cardiovascular and Physical Activity Monitoring: A Validation Study in Digital Health
Published on: February 21, 2025
Related Concept Videos
Exercise and Cardiac Output
Sustained exercise increases the muscles' oxygen demand, which can be...
Exercise Stress Test
Exercise stress testing, commonly known as a treadmill test, is a noninvasive procedure used to evaluate cardiovascular function and diagnose heart conditions.
Definition
An exercise stress test measures the heart's response to exertion using a treadmill or stationary bicycle. Chest electrodes record the heart's electrical activity through an ECG, and blood pressure is monitored regularly.
Purposes
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Exercise and Cardiovascular Response
Light to moderate physical activity initiates a series of interconnected responses in the body. The heart rate modestly increases in anticipation of the workout, followed by widespread vasodilation as oxygen consumption by skeletal muscles increases. This results in decreased peripheral resistance, increased capillary blood flow, and accelerated...
Thermal Stress
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...