Related Experiment Video
Updated: Jul 7, 2026

Measurement of Vibration Detection Threshold and Tactile Spatial Acuity in Human Subjects
Published on: September 1, 2016
Experimental investigation of sensitivity changes during encapsulation of piezoelectric composite materials
Rytis Mitkus1, Vilius Kesminas1, Markus Böl2
1Institute of Mechanics and Adaptronics, Technische Universität Braunschweig, D-38106, Braunschweig, Germany.
Abstract:
Piezoelectric (0-3) composites typically consist of a polymer matrix that contains piezoceramic particles. They can be used as sensors for structural health monitoring due to their lower acoustic impedance and ability to detect high-frequency waves. These composites have two thin electrodes on their surfaces, and cable connections that require electrical insulation. This insulation increases the durability of the sensor and provides additional protection. One way to achieve this is by encapsulating the sensor in polymer films. However, the sensitivity of the sensor may decrease due to an increase in overall stiffness after encapsulation, so this must also be evaluated. This study experimentally investigates and compares three different encapsulation designs with a non-encapsulated reference sample. The designs include (i) gluing and laminating the sensor onto a pre-prepared flexible printed circuit board, (ii) lamination of the sensor with polyethylene terephthalate, and (iii) lamination with polyetherimide. The sensitivity of the encapsulated sensors to low and high frequency vibrations was evaluated. The results show that an encapsulation sensor with adhesive tape and polyetherimide results in slightly lower sensitivity at lower frequencies, but almost no difference at higher frequencies. These results suggest that the proposed method is suitable for encapsulating sensors for use in structural health monitoring applications.
More Related Videos
07:44Characterization of Full Set Material Constants and Their Temperature Dependence for Piezoelectric Materials Using Resonant Ultrasound Spectroscopy
Published on: April 27, 2016
05:30Roughness Impact of Piezoelectric Dental Scaler on Two Distinct Flowable Composite Filling Materials
Published on: January 10, 2025
Related Concept Videos
Capacitor With A Dielectric
Dielectrics are non-conducting materials with no free or loosely bound electrons. When a dielectric is...
Dielectric Polarization in a Capacitor
Susceptibility, Permittivity and Dielectric Constant
Electrical Conductivity
In a practical conductor, an applied electric field may be sustained, causing a flow of electrons, which produce a current. The differential form of the current, the current density, is related to the electric field.
More generally, it is related to the force per unit charge, which involves the...
Potentiometry: Membrane Electrodes