Related Experiment Video
Updated: Sep 9, 2025

Artificial Lung Device Priming for In Situ Fiber Bundle Surface Grafting
Published on: March 28, 2025
Fibrosis 4 Index Predicts Haemocompatibility-Related Adverse Events in Patients Using Left Ventricular Assist Devices
Takahiro Kurihara1, Eisuke Amiya1, Masaru Hatano1,2
1Department of Cardiovascular Medicine, Graduate School of Medicine, The University of Tokyo, Tokyo 113-8655, Japan.
Background:
This study aimed to explore the association between the liver fibrosis-4 (FIB4) index and clinical events, specifically haemocompatibility-related adverse events (HRAEs), in patients who underwent left ventricular assist device (LVAD) implantation.
Methods:
The study involved patients who received LVADs for advanced heart failure (HF) treatment. FIB4 index was calculated both preoperatively and postoperatively, and its association with clinical events was examined, focusing on all-cause mortality and HRAEs, which included severe bleeding, cerebrovascular accidents, and intra-pump thrombosis.
Results:
A total of 224 patients with LVAD were analyzed. The value of FIB4 index was significantly decreased after LVAD implantation, and the postoperative FIB4 index was independently associated with composite events, including all-cause death and HRAEs after adjustment of cofounders. Next, we clarified the association between postoperative FIB4 index and clinical events after LVAD implantation. Patients were divided into 2 groups based on a postoperative FIB4 index threshold of 1.45. The high FIB4 group was associated an elevated risk of HRAEs (P = 0.0038), with no significant difference in survival curves between the groups. Additionally, the high FIB4 group showed elevated von Willebrand factor activity, while no significant differences were found in prothrombin time international normalized ratio variability.
Conclusions:
FIB4 index, a liver fibrosis marker, serves as a valuable prognostic indicator for HRAEs in patients receiving LVAD support.
More Related Videos
08:44An In Vitro Hemodynamic Loop Model to Investigate the Hemocytocompatibility and Host Cell Activation of Vascular Medical Devices
Published on: August 21, 2020
09:41Hemocompatibility Testing of Blood-Contacting Implants in a Flow Loop Model Mimicking Human Blood Flow
Published on: March 5, 2020
Related Concept Videos
Pathophysiology of Heart Failure
Heart Failure VI: Adjunct Therapies
Heart Failure IV: Classification and Diagnostic Evaluation
Cardiomyopathy V: Interprofessional Care