Related Experiment Video
Updated: Jul 21, 2026

Distinctive Capillary Action by Micro-channels in Bone-like Templates can Enhance Recruitment of Cells for Restoration of Large Bony Defect
Published on: September 11, 2015
Efficacy of 3D-Printed Bioactive Glass Tetrahedral Particles for Vertical Bone Regeneration: A Comparative Study
Wenjie Wang1,2, Liya Ai1, Lingling Zheng1
1Key Laboratory of Biomechanics and Mechanobiology(Beihang University), Ministry of Education; Key Laboratory of Innovation and Transformation of Advanced Medical Devices, Ministry of industry and Information Technology; National Medical Innovation Platform for industry-Education Integration in Advanced Medical Devices (Interdiscipline of Medicine and Engineering); School of Biological Science and Medical Engineering, School of Engineering Medicine, Beihang University, Beijing, China.
Abstract:
This study was designed to systematically evaluate the osteogenic efficacy of 3D-printed tetrahedral bioactive glass particles in vertical bone regeneration and compare their performance with that of conventional bone substitute materials. In this investigation, 3D tetrahedral bioactive glass particles were fabricated using digital light processing (DLP) additive manufacturing technology. The structural integrity and chemical composition of the particles were characterized by scanning electron microscopy (SEM), energy-dispersive spectroscopy (EDS), and X-ray diffraction (XRD) to confirm their conformity to design specifications. Additionally, three commercially available bone substitutes-Bio-Oss, PerioGlas, and Osteon-were employed as control materials for comparative analysis. In the experimental phase, four types of particulate materials were loaded into titanium buckets, which were then implanted on the calvarial surface of New Zealand white rabbits with surgically drilled cortical perforations at the implantation site. Micro-computed tomography (micro-CT) and histological evaluations were performed at 4 weeks and 12 weeks post-implantation. The results demonstrated that at 4 weeks, the height of new bone formation induced by the 3D-printed tetrahedral bioactive glass particles was 4.67 ± 0.34 mm, with a new bone proportion of 12.42% ± 3.81% and a new bone marrow proportion of 11.58% ± 1.63%. By 12 weeks, no statistically significant differences were observed among the groups in terms of new bone height, new bone proportion, or new bone marrow proportion. However, the 3D-printed particles exhibited a more homogeneous distribution of newly formed bone tissue. The osteogenic efficacy of 3D-printed tetrahedral bioactive glass particles in vertical bone regeneration is comparable to that of traditional bone substitute materials. However, their distinctive tetrahedral structure offers superior uniformity in bone growth. These results indicate that 3D printing technology holds promise for the development of bone substitute materials and merits further optimization as well as clinical translation.
More Related Videos
08:41Calvarial Model of Bone Augmentation in Rabbit for Assessment of Bone Growth and Neovascularization in Bone Substitution Materials
Published on: August 13, 2019
10:19Ceramic Omnidirectional Bioprinting in Cell-Laden Suspensions for the Generation of Bone Analogs
Published on: August 8, 2022