Related Experiment Video
Updated: Jun 12, 2026

C-arm-Free Simultaneous OLIF51 and Percutaneous Pedicle Screw Fixation in a Single Lateral Position
Published on: September 16, 2022
Modified serrated-tip cannulated screwdriver as a sleeve for anterior column screw insertion in percutaneous
Ali Fergany1, Bahaaeldin Ibrahim2, Ahmed A Khalifa3
1Orthopaedic Department, Assiut University Trauma Hospital, Faculty of Medicine, Assiut University, Egypt.
Abstract:
Percutaneous fixation of certain types of acetabular fractures is a valid, minimally invasive, and successful procedure. However, the technique for proper insertion of such screws is sensitive and requires adequate understanding of radiographic images. Furthermore, an optimum entry point and trajectory of the screws should be guaranteed to avoid hip joint penetration and screws misplacement. Various tools and techniques were described; we provide a technical note describing a modification on the tip of the cannulated screwdriver where serrations were added, which helped in better stability over the bone while inserting the guidewires for screws insertion, besides protecting the soft tissue envelope, especially in obese patients. We presented two early cases, one with a pure anterior column fracture and the other with a combined anterior column fracture and disruption of the sacroiliac joint on the same side, where we used the technique we described to ease percutaneous insertion of an anterior column screw for acetabular fracture fixation.