Investigation of the relationship between TIMI frame count, Tp-E interval duration and Tp-E/QT ratio in patients with

Murat Erdem Alp1, Mustafa Feridun Koşar1, Ece Çelebi Coşkun1

  • 1Bakırköy Dr. Sadi Konuk Training and Research Hospital, Bakırköy, İstanbul, Turkey.

Acta Cardiologica
|September 1, 2025
PubMed

Insights

Corrected TIMI frame count, a measure of coronary blood flow, inversely correlates with Tp-e interval and Tp-e/QT ratio in STEMI patients post-revascularization. These non-invasive ECG parameters may predict slow coronary flow.

Area of Science:

  • Cardiology
  • Interventional Cardiology
  • Cardiac Electrophysiology

Background:

  • Corrected TIMI frame count (Thrombolysis In Myocardial Infarction) objectively assesses coronary blood flow.
  • ST Elevation Myocardial Infarction (STEMI) patients often experience impaired coronary perfusion.
  • Evaluating post-revascularization flow is crucial for STEMI patient outcomes.

Purpose of the Study:

  • To investigate the relationship between corrected TIMI frame count and non-invasive electrocardiographic parameters (Tp-e interval, Tp-e/QT ratio).
  • To assess the utility of Tp-e interval and Tp-e/QT ratio in predicting slow coronary blood flow after revascularization in STEMI patients.

Main Methods:

  • Retrospective analysis of STEMI patients undergoing revascularization.
  • Measurement of post-procedure corrected TIMI frame count via coronary angiography.
  • Recording of pre- and post-procedure Tp-e interval and Tp-e/QT ratios from ECGs.

Main Results:

  • An inverse correlation was found between changes in corrected TIMI frame count and changes in Tp-e interval (r=-0.349, p=0.001).
  • A similar inverse correlation was observed between corrected TIMI frame count and Tp-e/QT ratio (r=-0.343, p=0.002).
  • Significant differences in Tp-e interval (p=0.003) and Tp-e/QT ratios (p=0.023) were noted between groups with corrected TIMI frame count above and below 27.

Conclusions:

  • Non-invasive Tp-e interval and Tp-e/QT ratio show an inverse correlation with corrected TIMI frame count post-STEMI revascularization.
  • These ECG parameters may serve as valuable non-invasive markers for assessing coronary antegrade blood flow.
  • TP-e interval and Tp-e/QT ratio could potentially replace invasive corrected TIMI frame count measurements.
Abstract

Related Concept Videos

Acute Coronary Syndrome I: Introduction01:30

Acute Coronary Syndrome I: Introduction

Acute Coronary Syndrome (ACS) encompasses a spectrum of heart conditions caused by sudden obstruction of coronary arteries, typically resulting from the rupture of an atherosclerotic plaque and subsequent thrombus (blood clot) formation. This obstruction can lead to partial or complete blockage of blood flow, causing varying degrees of myocardial ischemia or infarction.ACS includes the following clinical entities:Unstable Angina (UA)Non-ST-Elevation Myocardial Infarction (NSTEMI)ST-Elevation...
71
Acute Coronary Syndrome III: Diagnostic Studies01:30

Acute Coronary Syndrome III: Diagnostic Studies

Diagnosing acute coronary syndrome or ACS begins with a thorough patient history. Notable symptoms include central, crushing chest pain radiating to the left arm, neck, jaw, or back, along with shortness of breath, sweating (diaphoresis), nausea, vomiting, dizziness, and palpitations.It is crucial to note any history of cardiac illnesses and assess risk factors, including age, gender, smoking, hypertension, diabetes, hyperlipidemia, and a sedentary lifestyle.During physical examination, vital...
23
ECG Interpretation of Rhythms01:24

ECG Interpretation of Rhythms

An electrocardiogram (ECG)graphically represents the heart's electrical activity on ECG paper or a monitor.
Components of the Electrocardiogram
The primary components of a normal ECG waveform in Normal sinus rhythm(NSR) include the P wave, PR interval, QRS complex, ST segment, T wave, and occasionally a U wave.
ECG waveforms are divided by vertical and horizontal lines at standard intervals.
The horizontal axis measures time and rate, and the vertical axis measures amplitude or voltage....
3.8K