Correction: A dual-ion-selective electrode system for real-time monitoring of dissolved ammonia
Ayman H Kamel1,2, Hisham S M Abd-Rabboh3
1Department of Chemistry, College of Science, University of Bahrain, Sakhir 32038, Kingdom of Bahrain. ahkamel76@sci.asu.edu.eg.
The Analyst
|September 1, 2025
Abstract:
Correction for 'A dual-ion-selective electrode system for real-time monitoring of dissolved ammonia' by Ayman H. Kamel et al., Analyst, 2025, https://doi.org/10.1039/d5an00647c.
Related Concept Videos
Potentiometry: Membrane Electrodes
781
Membrane electrodes, also known as p-ion electrodes, use membranes that selectively interact with free analyte ions, generating a potential difference across the membrane. The resulting membrane potential, known as the asymmetry potential, is not zero even when analyte concentrations on both sides of the membrane are equal. The membrane's response is typically not selective to a single analyte but proportional to the concentration of all ions in the sample solution capable of interacting at...
781
Potentiometry: Types of Electrodes
919
Reference electrodes serve as a stable reference point for potentiometric measurements, while indicator and working electrodes react to variations in the composition of a solution.
The Standard Hydrogen Electrode (SHE) is a widely used reference electrode that maintains zero potential across all temperatures. However, its need for a continuous hydrogen gas supply renders it impractical for everyday use.
An alternative to SHE is the Saturated Calomel Electrode (SCE). This electrode features an...
The Standard Hydrogen Electrode (SHE) is a widely used reference electrode that maintains zero potential across all temperatures. However, its need for a continuous hydrogen gas supply renders it impractical for everyday use.
An alternative to SHE is the Saturated Calomel Electrode (SCE). This electrode features an...
919
Amperometry: Overview
740
Amperometry is a technique commonly used to measure the concentration of specific analytes in a solution by monitoring the electric current generated during an electrochemical reaction. It involves applying a constant potential between a working electrode and a reference electrode to measure the resulting current, which is proportional to the concentration of the analyte. The Clark oxygen electrode operates based on this principle of amperometry. It consists of a cathode and an anode enclosed...
740
Electrodes: Overview
1.9K
Electrochemical measurements are conducted in an electrochemical cell composed of various components that control and measure the current and potential. One fundamental component is electrodes, conductive materials that enable electron transfer reactions at their surfaces.
There are two main types of electrodes in electrochemical cells. The first type, known as the working or indicator electrode, has a potential that is sensitive to the analyte's concentration and reacts to changes in...
There are two main types of electrodes in electrochemical cells. The first type, known as the working or indicator electrode, has a potential that is sensitive to the analyte's concentration and reacts to changes in...
1.9K
Titration of a Weak Base with a Strong Acid
5.6K
The titration curve of a weak base like ammonia with a strong acid like hydrochloric acid is the mirror image of the titration curve of a weak acid with a strong base.
Using the ICE table and substituting the Kb value, we calculate the initial pH of 50 mL of 0.1 M ammonia to be 11.11. Addition of 25 mL of 0.1 M hydrochloric acid to this solution of ammonia results in a buffer with an equal concentration of ammonia and ammonium ions. The pH of this buffer can be calculated by substituting these...
Using the ICE table and substituting the Kb value, we calculate the initial pH of 50 mL of 0.1 M ammonia to be 11.11. Addition of 25 mL of 0.1 M hydrochloric acid to this solution of ammonia results in a buffer with an equal concentration of ammonia and ammonium ions. The pH of this buffer can be calculated by substituting these...
5.6K
EDTA: Indirect and Alkalimetric Titration
1.1K
Unlike direct titration, back-titration, and displacement titration, indirect titration is an EDTA titration method for quantifying anions. In the indirect titration method, anions are precipitated as their insoluble salts with excess metal ions. The filtrate containing the excess metal ions is directly titrated with standard EDTA until the endpoint is achieved. Another approach involves extracting the metal ion and back-titrating with standard EDTA to obtain the endpoint. In this way, the...
1.1K