Comparative study of advanced hydrogen liquefaction using triple cascade mixed refrigerant cycles with integrated
M Shawky Ismail1, M Abd ElSalam ElSeuofy2, Abd ElHamid Attia1
1Mechanical Engineering Department, Faculty of Engineering, Alexandria University, Alexandria, 21544, Egypt.
Abstract:
Hydrogen, as a clean energy source, is recognized as a pivotal energy carrier in the global transition to sustainable energy systems and serves as a crucial pathway for energy storage and efficient utilization within cryogenic systems. Hydrogen liquefaction is one of the most promising methods for increasing its energy density, enabling more efficient storage, transportation, and utilization in large-scale energy systems. However, substantial challenges persist, particularly regarding the high energy consumption associated with the liquefaction process. This study addresses these challenges by proposing two designs for a triple-cascade mixed refrigerant cycle aimed explicitly at reducing energy consumption for high-density hydrogen storage: 66.7 kg/m3 at - 245 °C (Case 1) and 76 kg/m3 at - 249 °C (Case 2). The proposed systems utilize two mixed refrigerant cycles for the precooling and cryogenic stages. In Case 1, pure nitrogen is employed as the third refrigerant in the precooling stage, whereas Case 2 incorporates a regenerative cryogenic hydrogen cycle as the third refrigerant throughout the entire system, coupled with a carbon dioxide cycle for compressor cooling. Simulations were conducted using Aspen HYSYS, with optimization through the Aspen Optimizer algorithm. The results indicate that Case 1 achieves a specific energy consumption (SEC) of 6.98 kWh/kgH₂, representing a 17.4% reduction from the baseline, while Case 2 reduces SEC to 6.19 kWh/kgH₂, a 14.5% decrease. The exergy analysis of the heat exchangers shows a 37% reduction in exergy destruction in Case 2 compared to Case 1. Additionally, Case 2 demonstrates a 5.8% reduction in capital expenditure and a 22% reduction in carbon footprint (CFP). These findings highlight the potential of the proposed triple-cascade process to enhance energy efficiency, improve both thermodynamic and economic performance, and reduce environmental impact.
Related Concept Videos
Refrigerators and Heat Pumps
A household refrigerator removes heat from...
Hess's Law
Free Energy Changes for Nonstandard States
where R is the gas constant (8.314 J/K·mol), T is the absolute temperature in kelvin, and Q is the reaction quotient. This equation may be used to predict the spontaneity of a process under any given set of conditions.
Reaction Quotient...
Efficiency of The Carnot Cycle
The Carnot Cycle
What could be the theoretical limit to the efficiency of a heat engine? The...
Reduction of Alkenes: Asymmetric Catalytic Hydrogenation
The metal catalyst used can be either heterogeneous or homogeneous. When hydrogenation of an alkene generates a chiral center, a pair of enantiomeric products is expected to form. However, an enantiomeric excess of one of the products can be facilitated using an enantioselective reaction or an...