Related Experiment Video
Updated: May 2, 2026

A Volumetric Method for Quantification of Cerebral Vasospasm in a Murine Model of Subarachnoid Hemorrhage
Published on: July 28, 2018
Vessel segmentation for χ $$ \chi $$ -separation in quantitative susceptibility mapping
Taechang Kim1, Sooyeon Ji1,2, Kyeongseon Min1
1Laboratory for Imaging Science and Technology, Department of Electrical and Computer Engineering, Seoul National University, Seoul, Republic of Korea.
Purpose:
-separation is an advanced quantitative susceptibility mapping (QSM) method that is designed to generate paramagnetic ( ) and diamagnetic ( ) susceptibility maps, reflecting the distribution of iron and myelin in the brain. However, vessels have shown artifacts, interfering with the accurate quantification of iron and myelin in applications. To address this challenge, a new vessel segmentation method for -separation is developed.
Methods:
The method comprises three steps: (1) seed generation from and the product of and maps; (2) region growing, guided by vessel geometry, creating a vessel mask; (3) refinement of the vessel mask by excluding non-vessel structures. The performance of the method was compared to other vessel segmentation methods both qualitatively and quantitatively. To demonstrate the utility of the method, it was tested in two applications: quantitative evaluation of a neural network-based -separation reconstruction method ( -sepnet- ) and population-averaged region of interest (ROI) analysis.
Results:
The proposed method demonstrates superior performance to other vessel segmentation methods, effectively excluding the non-vessel structures, achieving the highest Dice score coefficient against manually segmented vessel masks (3 T: 76.7% for and 68.7% for , 7 T: 76.9% for and 72.6% for ). For the applications, applying vessel masks report notable improvements for the quantitative evaluation of -sepnet- and statistically significant differences in population-averaged ROI analysis. These applications suggest excluding vessels when analyzing the -separation maps provide more accurate evaluations.
Conclusion:
The proposed method has the potential to facilitate various applications, offering reliable analysis through the generation of a high-quality vessel mask.
Related Concept Videos
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
High-Performance Liquid Chromatography: Elution Process
High-Performance Liquid Chromatography: Instrumentation
High-Performance Liquid Chromatography: Types of Detectors
Ion-Exchange Chromatography
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...