Related Experiment Video
Updated: Sep 9, 2025

Author Spotlight: Optimized Lung MRI Protocol with Computationally Efficient Reconstruction Methods
Published on: September 6, 2024
Comparing respiratory-triggered T2WI MRI with an artificial intelligence-assisted technique and motion-suppressed
Nan Wang1, Yuhui Liu2, Jiangnan Ran1
1Department of Radiology, The First Affiliated Hospital of Dalian Medical University, Dalian, China.
Background:
Magnetic resonance imaging (MRI) plays a crucial role in the diagnosis of abdominal conditions. A comprehensive assessment, especially of the liver, requires multi-planar T2-weighted sequences. To mitigate the effect of respiratory motion on image quality, the combination of acquisition and reconstruction with motion suppression (ARMS) and respiratory triggering (RT) is commonly employed. While this method maintains image quality, it does so at the expense of longer acquisition times. We evaluated the effectiveness of free-breathing, artificial intelligence-assisted compressed-sensing respiratory-triggered T2-weighted imaging (ACS-RT T2WI) compared to conventional acquisition and reconstruction with motion-suppression respiratory-triggered T2-weighted imaging (ARMS-RT T2WI) in abdominal MRI, assessing both qualitative and quantitative measures of image quality and lesion detection.
Methods:
In this retrospective study, 334 patients with upper abdominal discomfort were examined on a 3.0T MRI system. Each patient underwent both ARMS-RT T2WI and ACS-RT T2WI. Image quality was analyzed by two independent readers using a five-point Likert scale. The quantitative measurements included the signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), peak signal-to-noise ratio (PSNR), and sharpness. Lesion detection rates and contrast ratios (CRs) were also evaluated for liver, biliary system, and pancreatic lesions.
Results:
There ACS-RT T2WI protocol had a significantly reduced median scanning time compared to the ARMS-RT T2WI protocol (148.22±38.37 vs. 13.86±1.72 seconds). However, ARMS-RT T2WI had a higher PSNR than ACS-RT T2WI (39.87±2.72 vs. 38.69±3.00, P<0.05). Of the 201 liver lesions, ARMS-RT T2WI detected 193 (96.0%) and ACS-RT T2WI detected 192 (95.5%) (P=0.787). Of the 97 biliary system lesions, ARMS-RT T2WI detected 92 (94.8%) and ACS-RT T2WI detected 94 (96.9%) (P=0.721). Of the 110 pancreatic lesions, ARMS-RT T2WI detected 102 (92.7%) and ACS-RT T2WI detected 104 (94.5%) (P=0.784). The CR analysis showed the superior performance of ACS-RT T2WI in certain lesion types (hemangioma, 0.58±0.11 vs. 0.55±0.12; biliary tumor, 0.47±0.09 vs. 0.38±0.09; pancreatic cystic lesions, 0.59±0.12 vs. 0.48±0.14; pancreatic cancer, 0.48±0.18 vs. 0.43±0.17), but no significant difference was found in others like focal nodular hyperplasia (FNH), hepatapostema, hepatocellular carcinoma (HCC), cholangiocarcinoma, metastatic tumors, and biliary calculus.
Conclusions:
ACS-RT T2WI ensures clinical reliability with a substantial scan time reduction (>80%). Despite minor losses in detail and SNR reduction, ACS-RT T2WI does not impair lesion detection, marking its efficacy in abdominal imaging.
More Related Videos
09:08Author Spotlight: Standardization and Best Practices for Advancing Lung Imaging Using 129Xe MRI
Published on: November 21, 2023
06:53Management of Respiratory Motion Artefacts in 18F-fluorodeoxyglucose Positron Emission Tomography using an Amplitude-Based Optimal Respiratory Gating Algorithm
Published on: July 23, 2020
Related Concept Videos
Magnetic Resonance Imaging
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Imaging Studies for Cardiovascular System IV: CMRI