Thais da Costa Vinha1, Ana Paula Macedo1, Viviane de Cássia Oliveira1
1Department of Dental Materials and Prosthesis, Ribeirão Preto School of Dentistry, University of São Paulo, Ribeirão Preto, Brazil.
Background:
Cleaning overdentures is challenging due to their complex metallic structures, which often create small and irregular areas that are difficult to clean. Thus, it is necessary to find an effective and safe method for their maintenance.
Objectives:
The aim of the study was to evaluate the effects of hygiene methods on the dimensional changes and retention force of the O-ring system over a simulated two-year period.
Material And Methods:
A total of 54 specimens with 2 O-rings each were distributed into 9 groups: control - no cleaning; brushing - blue®m toothpaste (BM); brushing - Trihydral toothpaste (TR); immersion - NitrAdine® (Ni); immersion - 5 mg/mL chitosan solution (Ch); and combined methods: BM+Ni, BM+Ch, TR+Ni, TR+Ch. The deformation and retention force were evaluated every 6 months for 2 years. The statistical analysis was performed using two-way analysis of variance (ANOVA) and Pearson's correlation test (α = 0.05).
Results:
The BM+Ch group exhibited smaller changes in diameter after 6 months (Δ(T1-T0)) than the control and BM+Ni groups, both internally and externally (p < 0.001). In addition, the BM+Ch group demonstrated greater retention forces at 6 months (p = 0.024) and 18 months (p = 0.028) in comparison to the TR+Ch group. The TR+Ch group exhibited a negative correlation with changes in the external diameter (r = -0.334, p = 0.021), while BM+Ch showed a negative correlation with changes in the internal diameter (r = -0.334, p = 0.021). The Ni group demonstrated a negative relationship with changes in both the internal (r = -0.296, p = 0.041) and external diameters (r = -0.405, p = 0.004).
Conclusions:
A combination of brushing with blue®m toothpaste and immersion in the chitosan solution demonstrated satisfactory results in maintaining the retention force of the O-ring system.
More Related Videos
08:47Mimicking and Measuring Occlusal Erosive Tooth Wear with the "Rub&Roll" and Non-contact Profilometry
Published on: February 2, 2018
07:42Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Published on: December 20, 2024
Related Concept Videos
Hand hygiene
Hand washing...
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
Assessment of the Mouth
Mouth Inspection
The inspection begins with visually examining the mouth for symmetry, color, and size.