Related Experiment Video
Updated: Sep 9, 2025

Diagnosis of Musculus Gastrocnemius Tightness - Key Factors for the Clinical Examination
Published on: July 7, 2016
Is the weight-bearing lunge test a better tool for assessing ankle mobility in chronic venous insufficiency? A
Iane Renata Carvalhais Mesquita1, Yasmmin França Eliziário2, Sofia Fróis Fernandes de Oliveira2
1Postgraduate Program in Reabilitação e Desempenho Funcional, Universidade Federal dos Vales do Jequitinhonha e Mucuri (UFVJM), Diamantina, Brazil.
Abstract:
ObjectivesPatients with chronic venous insufficiency (CVI) often present with limited mobility, which can lead to pain, edema, and reduced ankle range of motion (ROM). The aim of the present study was to compare the inter-rater reliability and construct validity of the Weight-Bearing Lunge Test (WBLT) and traditional goniometry in assessing ankle dorsiflexion ROM in individuals with CVI.MethodsA cross-sectional study was conducted with 54 patients with CVI (66 ± 11 years; CEAP 1 to 6). Ankle dorsiflexion was assessed by two independent evaluators using goniometry and the WBLT. Functional performance was evaluated using the 5-repetition Sit-to-Stand Test (STS5) for strength, the 60-s Sit-to-Stand Test (STS60) for endurance, the Heel Rise Test (HRT) for calf muscle endurance, the Human Activity Profile (HAP) for activity level, and calf circumference. Inter-examiner reliability was determined using the Intraclass Correlation Coefficient (ICC), and validity was assessed through correlations between WBLT, goniometry, and functional variables.ResultsGoniometry demonstrated good inter-examiner reliability (ICC = 0.77), while WBLT showed excellent reliability (ICC = 0.98). WBLT correlated significantly with goniometry (r = -0.320; p = .020), HAP (r = 0.563), HRT (r = 0.378), STS5 (r = -0.605), and STS60 (r = 0.550) (all p < .001), whereas goniometry did not correlate with any functional outcomes.ConclusionsThe WBLT demonstrated superior inter-examiner reliability and more substantial validity compared to goniometry, supporting its use as a reliable and clinically relevant tool for assessing dorsiflexion ROM in patients with CVI.
Related Concept Videos
Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Assessing Blood pressure in the Leg
Preparation:
Ankle Joint
Pulse Assessment Sites
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation

