Detection of actinides in wound swabs by the measurement of spontaneously emitted characteristic x-rays
Related Experiment Video
Updated: Sep 9, 2025

A Novel Technique for Raman Analysis of Highly Radioactive Samples Using Any Standard Micro-Raman Spectrometer
Published on: April 12, 2017
Yudai Ogawa1,2, Ukyou Yanagisawa2,3, Hui Wang2
1Faculty of Engineering Division of Engineering Human and Artificial Intelligent Systems, University of Fukui, 3-9-1 Bunkyo, Fukui, Fukui 910-8507, Japan.
Abstract:
In the event of an accident at a nuclear fuel handling facility, the wounds of the affected workers may be contaminated with actinides such as uranium, neptunium, plutonium, and americium. The accidental absorption of actinides from wounds can lead to a significant degree of internal radiation exposure, which can be hazardous to the human body. Although the current approach for identifying actinide contamination is based on the detection ofα-particles, the applicability of this approach is reduced for wound contamination due to theα-particles being easily shielded by various components of bodily fluid. Many actinide nuclides spontaneously emit characteristic x-rays during internal conversion after nuclear decay. X-rays are more penetrating thanα-particles and may be easily detected even in the presence of blood. Thus, in the current study, the effects of blood on the measurement ofα-particles and spontaneously emitted characteristic x-rays were evaluated using model wound swab samples containing human blood along with241Am, which exhibits a high emission rate of characteristic x-rays. Unlike inα-particle measurements, no blood effects were observed during the measurement of spontaneously emitted characteristic x-rays. Additionally, blood-free x-ray measurements were performed using model wound swab samples containing241Am along with239Pu +240Pu, which are important nuclides when considering internal exposure to actinides. In the measured spectra, signals derived from plutonium and americium were separated by peak fitting, and the detection limit of plutonium was estimated to be ∼18.8 Bq during a 300 s measurement. Notably, no previously reported methods can detect plutonium in wound swabs with such sensitivity and accuracy without pretreatment. Moreover, the developed approach allows detection using a palm-sized device, thereby reflecting a clear advantage in terms of portability and compactness.
More Related Videos
Related Concept Videos
Atomic Emission Spectroscopy: Lab
Atomic Emission Spectroscopy: Overview
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing...
Atomic Absorption Spectroscopy: Radiation and Light Sources
Two common narrow-range 'line' sources used in AAS are hollow-cathode lamps (HCLs) and...
Atomic Absorption Spectroscopy: Overview
When irradiated by EMR of a particular wavelength, these...
X-ray Imaging

