Related Experiment Video
Updated: May 7, 2026

Fabrication And Characterization Of Photonic Crystal Slow Light Waveguides And Cavities
Published on: November 30, 2012
On-chip near-infrared gas sensing based on slow light mode multiplexing in photonic crystal waveguides
Zihang Peng1, Yuting Min1, Mingquan Pi1
1State Key Laboratory of Integrated Optoelectronics, College of Electronic Science and Engineering, Jilin University, Changchun 130012, China. zhengchuantao@jlu.edu.cn.
Abstract:
Photonic crystal slow light waveguides present a breakthrough in the manipulation of optical signals and enhancing the interaction between light and matter. In particular, two-dimensional (2D) photonic crystal waveguides (PCWs) on silicon photonic chips hold promise in improving the sensitivity of on-chip gas sensors. However, the development of the gas sensors based on 2D PCWs suffers from a high propagation loss and a narrow slow light bandwidth. In this study, our focus was on designing a one-dimensional (1D) PCW with lower propagation loss and tailored group indices across dual distinct frequency bands. To achieve this, a mode converter was employed to effectively stimulate both odd and even modes of the 1D PCW with odd modes ranging from 1520 to 1555 nm and even modes spanning 1615-1665 nm. Remarkably, we pioneered the application of slow light mode multiplexing to demonstrate the potential of the 1D PCW as an on-chip multi-gas sensor, specifically targeting acetylene (C2H2) and methane (CH4). At 1533 nm, the odd mode exhibited an impressive interaction factor of 0.836; while at 1654 nm, the even mode achieved an even higher interaction factor of 1.308, and both retain relatively low propagation losses. This research not only introduces innovative strategies for expanding slow light bandwidth, but also presents a promising avenue for on-chip multi-gas detection.
Related Concept Videos
Infrared (IR) Spectroscopy: Overview
Different compounds display unique properties due to their...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Types of Detectors-II
Fluorescence and Phosphorescence: Instrumentation
Determination of Crystal Structures

