Real-World Listening Experiences of Hearing Aid Users Are Associated With In Situ Heart Rate and Acoustic Data
Klaudia Edinger Andersson1,2, Jeppe Høy Christensen3, Rasmus P Skipper4
1Department of Clinical Research, University of Southern Denmark, Odense.
Background:
Ecological momentary assessment (EMA) combined with acoustic data logging can provide insights into the real-world listening experiences of hearing aid (HA) users. Previous research conducted on individuals with normal hearing has shown that higher sound pressure level (SPL) and lower signal-to-noise ratio (SNR) to be associated with poorer EMA ratings. Furthermore, including listening intent in the analyses revealed higher heart rate to be linked with better EMA ratings during focused listening compared to nonfocused listening. The current study explored if corresponding associations can be observed for HA users.
Method:
Sixteen experienced HA users completed smartphone-based EMAs during a 2-week trial period. EMAs related to general listening experience and perceived noisiness of the surroundings were collected. When completing the EMAs, the participants also indicated their listening intent (speech-focused, other-focused, or nonfocused listening). The participants were fitted with test HAs that included adaptive noise management and that provided in situ data of the ambient SPL and SNR. Continuous heart rate data were collected using wristbands worn by the participants.
Results:
Linear mixed-effects models showed that poorer general listening experiences were associated with higher SPL, lower SNR, and higher heart rate, while greater perceived noisiness was associated with higher SPL and lower SNR. When considering the influence of listening intent on these results, poorer general listening experiences and greater perceived noisiness were strongly associated with lower SNR during speech- and other-focused listening compared to nonfocused listening. Furthermore, poorer general listening experiences were associated with higher heart rate during other-focused listening.
Conclusions:
Louder and noisier environments impact the real-world listening experiences of HA users negatively, especially during focused listening. Overall, these results underscore the importance of the ambient acoustics and listening intent. Further research is needed to shed more light on the relations with heart rate.
More Related Videos
06:58An Application for Pairing with Wearable Devices to Monitor Personal Health Status
Published on: February 3, 2022
11:39Assessment of Audio-Tactile Sensory Substitution Training in Participants with Profound Deafness Using the Event-Related Potential Technique
Published on: September 7, 2022
Related Concept Videos
Heart Sounds
Auscultation is the process of listening to these internal body sounds using a stethoscope. The heart produces four types of sounds, but only two—S1 and S2—can usually be heard with a stethoscope.
S1, also known as the "lub" sound, is caused by the closure of atrioventricular (A-V)...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Assessment of the Cardiovascular System IV: Auscultation
Normal Heart Sounds
S1 (First Heart Sound)-
S1 is made by the closure of the mitral and tricuspid valves (atrioventricular valves), marking the beginning of systole.
S2 (Second Heart Sound)-
S2 is made by the closure of the aortic and pulmonic valves (semilunar valves), marking the end of the systole.