Efficacy of supraglottic airway devices in chest compression synchronized ventilation during continuous
Tamar Gelashvili1, Beate Brand-Saberi2, Mahsa Darvishali3
1Ruhr University Bochum, Medical Faculty of Ruhr University Bochum, Universitätstraße 150, 44801 Bochum, Germany; University Department of Anesthesiology, Intensive Care Medicine, Emergency Medicine and Pain Medicine, Johannes Wesling Klinikum Minden, Ruhr University Bochum, Hans-Nolte-Straße 1, 32429 Minden, Germany.
Background:
This study aimed to evaluate the efficacy of Chest-Compression-Synchronized-Ventilation (CCSV) using supraglottic airway devices (SGA) compared to tracheal intubation (TI) for ventilation during continuous resuscitation.
Methods:
In this cross-over study, the lungs of adult Thiel-embalmed cadavers were initially recruited using TI. Subsequently, various SGA (Laryngeal-Mask = Ambu®AuraGain™, Laryngeal-Tube = LTS-D®, i-gel-Laryngeal-Mask = I-GEL®) and TI were applied in randomized order during continuous chest compressions. CCSV was delivered with a CCSV-Pressure (pCCSV) = 40 mbar, PEEP = 3 mbar, respiratory-rate (RR) synchronized with the chest compression rate. The primary endpoint was achieving a pCCSV = 40 ± 3 mbar. Secondary endpoints included pCCSV, expiratory tidal (Vte) 1 ml/kgBW and leakage volumes (Vleak). Logistic regression models with random intercepts were used for the primary outcome, and linear mixed models were applied for secondary outcomes.
Results:
Eleven cadavers were included. While two(18 %) were successfully ventilated with all airway types, three(27 %) could only be ventilated with an TI. Two cadavers(18 %) could not be sufficiently ventilated with any of the airway devices including TI. When comparing TI and SGA, for TI a greater chance of reaching the target corridor of pCCSV (Odds Ratio(OR) = 1.87; 95 %-Confidence-Interval(95 %CI) = [0.91-3.83]; P = 0.0864) and a higher pCCSV was observed (regression-coefficient(RC) = 2.99 mbar; 95 %CI = [1.63-4.35]; p < 0.0001), along with a higher Vte (RC = 42.42 ml; 95 %CI = [32.07-52.27]; p < 0.0001), and a lower Vleak (RC = -55.03 %; 95 %CI = [-62.92-47.15]; p < 0.0001). In comparisons among the individual SGA, lower pCCSV-values were observed for Ambu®AuraGain™ versus I-GEL® (RC = -2.58 mbar; 95 %CI = [-4.04--1.13]; p = 0.0006), Ambu®AuraGain™ versus LTS-D® (RC = -1.73 mbar; 95 %CI = [-3.18--0.27]; p = 0.0204), and LTS-D® versus I-GEL® (RC = -0.86 mbar; 95 %CI = [-2.30-0.59]; p = 0.2434).
Conclusion:
SGA were associated with a lower likelihood of reaching the target range of pCCSV, lower Vte, and higher Vleak. Regardless the airway device, CCSV-failure is possible emphasizing the need for vigilant respiratory monitoring.
Registration:
URL: https://www.
Clinicaltrials:
gov. Unique identifier number: NCT06306898.
Related Concept Videos
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques
Cardiopulmonary Resuscitation II: ACLS Airway Management
Acute Respiratory Failure-V
Ensure that patients are monitored continuously for their response to therapy, including changes in...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Cardiopulmonary Resuscitation I: Adult