Concordance study between PowerPlex® ESI 16 Fast Kit and Investigator® 24plex GO! Kit
Yaara Levav Cohen1, Avigail Kleiman1, Aya Spitzer2
1DNA Database Laboratory, Division of Identification and Forensic Science (DIFS), Israel Police, Jerusalem, Israel.
Abstract:
Short tandem repeat (STR) analysis is the cornerstone of forensic human identification due to its high discriminatory power and robustness. A concordance study was conducted to evaluate allele call consistency between two STR multiplex kits: PowerPlex® ESI 16 Fast (Promega Corporation, Madison, WI, USA) and Investigator®24plex GO! Kit (QIAGEN GmbH, Hilden, Germany). A total of 2000 buccal FTA cards (Whatman™ Flinders Technology Associates, Cytiva, Marlborough, MA, USA) samples previously typed with the PowerPlex® ESI 16 Fast Kit were re-analyzed using the Investigator® 24plex GO! Kit. An overall concordance rate of 99.982% was observed (59,989 concordant allele calls out of 60,000 total calls). Eleven discordant alleles were identified, including five cases of allelic dropout at distinct loci, five instances of allele shift (typically between D1S1656 and the adjacent DYS391), and one true mismatch at D1S1656. All discordances were confirmed by repeated amplification using both the PowerPlex® ESI 16 Fast and Investigator® 24plex GO! Kits, as well as the Investigator® 24plex QS Kit (QIAGEN GmbH, Hilden, Germany). The mismatch at D1S1656 was further confirmed by sequencing. The low discordance rate supports the reliability of the Investigator® 24plex GO! Kit for forensic reference databasing and enables a confident transition from the PowerPlex® ESI 16 Fast Kit.
More Related Videos
05:53Candidate Gene Testing in Clinical Cohort Studies with Multiplexed Genotyping and Mass Spectrometry
Published on: June 21, 2018
05:58Digital Polymerase Chain Reaction Assay for the Genetic Variation in a Sporadic Familial Adenomatous Polyposis Patient Using the Chip-in-a-tube Format
Published on: August 20, 2018
Related Concept Videos
Conduction, Convection and Radiation: Problem Solving
In order to solve a problem related to heat transfer, first of all, the situation needs to be examined to determine the type of heat transfer involved. This could...
Electrical Conductivity
In a practical conductor, an applied electric field may be sustained, causing a flow of electrons, which produce a current. The differential form of the current, the current density, is related to the electric field.
More generally, it is related to the force per unit charge, which involves the...
Conduction System of the Heart
The pacemaker cells are located in two primary nodes: the sinoatrial (SA) node and the atrioventricular (AV) node. The SA node pacemaker cells can autonomously depolarize, triggering an action potential that leads to the...
Conduction System of the Heart
This system relies on the unique properties of nodal and Purkinje cells:...
