Related Experiment Video
Updated: Sep 9, 2025

A Protocol to Set Up Needle-Free Connector with Positive Displacement on Central Venous Catheter in Intensive Care Unit
Published on: July 13, 2019
Midline Catheters as an Alternative for Central Venous Catheters in Venous Pressure Monitoring: A Single Center
Brendan Sweeney1, Justin Kim2, Ariana Adnani1
1School of Medicine and Health Sciences, The George Washington University, Washington, DC, USA.
Abstract:
Purpose: Midline catheters (ML) are long peripheral intravenous catheters placed in an upper extremity above the antecubital fossa via the basilic, cephalic, or brachial veins. These provide safe and comfortable long-term vascular access for critically ill patients. Central venous pressures (CVP) are obtained from central venous catheters (CVC) and are often used as resuscitation parameters. Given the proximity of ML to the axillary vein, we investigated if midline venous pressure (MVP) is comparable to CVP. Methods: This is an observational study conducted in adult critical care patients at a tertiary academic center. Inclusion criteria were patients with a CVC in the subclavian or internal jugular veins and a ML in place as part of standard ICU care. Pressure measurements were recorded from both catheters every 15 min over a 60-min period. Demographic, clinical, and physiological data points were collected. Continuous variables were analyzed using the t-test. Pearson correlation was used to evaluate the relationship between the paired variables. Results: We enrolled 50 patients with 5 pressure measurements taken per patient (n = 250). The mean MVP and CVP were 10.6 ± 6.4 mm Hg and 9.1 ± 6.3 mm Hg, respectively (P < .001). In Bland Altman analysis, the mean bias was -1.48 ± 3.99 mm Hg with limits of agreement of -9.3 mm Hg to 6.3 mm Hg. The Pearson correlation coefficient was 0.8 (P < .001). Conclusions: Our study investigated MVP as a correlate of CVP. Our results show a mean bias of -1.48 ± 3.99 mm Hg and a strong positive Pearson correlation coefficient of 0.8 between the MVP and the CVP. The large limits of agreement indicate MVP and CVP are not interchangeable. Despite this, clinically significant pressure values from CVCs and MLs trend similarly.
More Related Videos
09:05Catheterization of the Carotid Artery and Jugular Vein to Perform Hemodynamic Measures, Infusions and Blood Sampling in a Conscious Rat Model
Published on: January 30, 2015
07:47The Supraclavicular Fossa Ultrasound View for Central Venous Catheter Placement and Catheter Change Over Guidewire
Published on: December 23, 2014
Related Concept Videos
Parentral Nutrition: Centeral and Peripheral Parental Nutrition
PN can be administered through two primary routes:
1. Central Parenteral Nutrition (CPN):
CPN involves delivering a high concentration of nutrients through a large vein. This is typically achieved using a Peripherally Inserted Central Catheter (PICC) or,...
Cardiac Catheterization II: Right Heart Catheterization
Venous Thrombosis III: Interprofessional Care
Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies
Cardiac Catheterization IV: Nursing Management