Related Experiment Video
Updated: Sep 9, 2025

Optimized Setup and Protocol for Magnetic Domain Imaging with In Situ Hysteresis Measurement
Published on: November 7, 2017
Application of particle swarm optimization to non-orthogonal error correction in SAFEM total magnetic intensity
Changsheng Liu1,2, Shaoyou Kan2, Xiaotian Liu2
1State Key Laboratory of Deep Earth Exploration and Imaging, Jilin University, Changchun 130026, People's Republic of China.
Abstract:
In the semi-airborne frequency-domain electromagnetic (SAFEM) method, the total magnetic intensity (TMI) is derived from the vector synthesis of triaxial inductive magnetic sensors. However, non-orthogonal errors in the sensors introduce measurement inaccuracies. Traditional calibration techniques are unsuitable for induction magnetic sensors because they require either static magnetic field measurements or complex alternating current reference fields. We propose a novel, high-precision calibration method based on an improved particle swarm optimization (IPSO) algorithm that circumvents the need for an external physical reference to address this challenge. This method establishes a mathematical model of the non-orthogonal error, transforming the calibration into an optimization problem that aims to minimize the root mean square error (RMSE) of the TMI. Simulation results demonstrate that the proposed IPSO algorithm exhibits higher convergence accuracy and stronger noise immunity compared with the standard PSO. Experiments with a physical measurement system further validated the method's efficacy: after calibration, the maximum absolute error and the RMSE of the TMI were significantly reduced by 82.84% and 87.64%, respectively. This study provides a critical technical solution for the complex, multi-parameter error calibration of alternating current vector magnetometers, ensuring the acquisition of high-precision TMI data for SAFEM systems.
Related Concept Videos
NMR Spectrometers: Resolution and Error Correction
Magnetostatic Boundary Conditions
Conservation of Angular Momentum: Application
Magnetic Susceptibility and Permeability
When diamagnetic materials are placed under an external magnetic field, the moments opposite to the field are induced. Hence, the susceptibility for diamagnets has a minimal negative value of 10-5–10-6. Since...
Magnetic Vector Potential
Consider an ideal solenoid with n turns per unit length and radius R. If I is the current through the solenoid, the magnetic field inside the solenoid is expressed as the product of vacuum...
Magnetic Field due to Moving Charges
Consider a point charge moving with a constant velocity. Like the electric field, the magnetic field at any point is directly proportional to the magnitude of the charge and inversely proportional to the square of the distance between the source point and the field point. However, unlike the electric field, the magnetic field is always perpendicular to the plane containing the line...

