Related Experiment Video
Updated: Sep 8, 2025

Author Spotlight: Advancing the Study of Brain-Heart Interplay with a Comprehensive EEGLAB Plugin for Multimodal Signal Analysis
Published on: April 26, 2024
Neck-focused Remote Photoplethysmography (rPPG): A comparative study using clinical data and the PyVHR framework
Coen Arrow1, Max Ward2, Jason Eshraghian3
1School of Medicine, University of Western Australia, 35 Stirling Hwy, Crawley, 6009, WA, Australia; Harry Perkins Institute of Medical Research, 5 Robin Warren Dr, Murdoch, 6150, WA, Australia.
Abstract:
Remote Photoplethysmography (rPPG) promises to turn digital cameras into medical devices with the measurement of heart rates, oxygen saturation and the diagnosis arrhythmias already demonstrated. The face-centric nature of current rPPG techniques limits open-datasets from including subjects with clinically-relevant cardiorespiratory conditions without sharing private medical information. The neck, with few identifiable characteristics, is well suited to overcoming this limitation, as it serves as a region of interest (ROI) for pulse detection during jugular venous examination, a common clinical technique. rPPG techniques hinge on the ability to accurately measure heart rates. This paper aims to motivate the development of neck-based rPPG technology by first showing that comparable heart-rate measurement accuracy can be achieved on the neck using rPPG algorithms developed for the face, and then investigating how subject posture affects measurement accuracy. We do this by using a version of the PyVHR framework adapted to process both necks and faces and using 20 different rPPG approaches. We introduce a novel metric, Heart-Rate Within Tolerance (HRWT) as a more intuitive metric for understanding the overall reliability of an rPPG approach. We found comparable heart rate measurement accuracy on a neck-centric dataset, compared with 5 face-centric datasets, with differences in mean absolute percentage error of 1.79 ± 4.93% BPM between the neck and faces. Neck videos were also found to have an improved HRWT, outperforming facial videos by an average of 15%. For neck-centric videos, subject posture was found to decrease performance as the subject moved from a supine, to seated position.
More Related Videos
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
08:12Calculating Heart Rate Variability from ECG Data from Youth with Cerebral Palsy During Active Video Game Sessions
Published on: June 5, 2019