Related Experiment Video
Updated: May 6, 2026

Proton Therapy Delivery and Its Clinical Application in Select Solid Tumor Malignancies
Published on: February 6, 2019
Comparative dosimetric analysis of base dose and gradient-based optimization in overlapping regions of extended
Dipesh1,2, Raj Pal Singh3, Manindra Bhushan4
1Department of Physics, GLA University, Mathura, Uttar Pradesh, India. d.vashisht700@gmail.com.
Abstract:
This study compares the dosimetric performance of Base Dose Optimization (BDO) and Gradient-Based Optimization (GBO) for extended target volumes in Total Body Irradiation (TBI). The focus is on overlapping regions using the Rando Phantom. The study evaluates dose distribution, conformity, homogeneity, and sensitivity to positional deviations. The Rando Phantom was used for treatment planning with both BDO and GBO plans. Positional shifts of ± 5 mm and ± 10 mm were introduced to assess uncertainties. Dosimetric metrics included mean dose, minimum dose, maximum dose, homogeneity index (HI), and conformity index (CI). Positional deviations and their impact on dose variations were analyzed. Quality assurance was performed using OSLDs and an array detector. The BDO plan delivered higher mean doses (103.6%-108.7%) and hotspot values, with a maximum of 133.7%. In contrast, the GBO plan produced a more uniform dose distribution (99.6%-100.3%) with lower hotspots, peaking at 112%. The BDO plan achieved better uniformity (HI 0.025-0.103) and higher conformity (CI 0.938-0.981). The GBO plan showed greater variability (HI 0.143-0.253) and slightly lower conformity (CI 0.941-0.964). Positional shifts revealed that the BDO plan was highly sensitive, with overdoses of + 46.60% and underdoses of - 47.29%. The GBO plan showed smaller deviations (+ 11.62% overdose, - 11.73% underdose). Gamma analysis demonstrated higher pass rates for the GBO plan. The BDO plan excels in target coverage and conformity but is sensitive to positional shifts. The GBO plan offers better uniformity and robustness, supporting its use in complex clinical scenarios. Further refinement of both approaches could improve clinical applicability and patient outcomes.
More Related Videos
09:49A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy PRRT: 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
Published on: April 24, 2020
07:57Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
Published on: March 24, 2022
Related Concept Videos
Model-Independent Approaches for Pharmacokinetic Data: Noncompartmental Analysis
One important characteristic of noncompartmental analyses is that drug exposure increases proportionally with increasing doses. This...
Measurement of Bioavailability: Pharmacodynamic Methods
Dosage Regimen Designs: Nomograms and Tabulations
Dose Size and Dosing Frequency: Determination Methods
Determination of Multiple Dosing Parameters: Steady-State, Minimum and Maximum Concentrations
Determination of Multiple Dosing Parameters: Loading and Maintenance Doses