Reliable and sensitive ultra-short chain per- and polyfluorinated alkyl substances (PFAS) analysis in food: a polar
Consolato Schiavone1, Francesco Romaniello1, Paola Brizio2
1Istituto Nazionale di Ricerca Metrologica (INRIM), Strada delle cacce 91, Turin, 10135, Italy.
Abstract:
Food contamination by per- and polyfluoroalkyl substances (PFAS), especially ultra-short-chain (USC) compounds, poses a growing concern due to their environmental persistence and potential health risks. Despite the developing regulatory framework, analytical challenges persist in quantifying polar USC-PFAS in complex content food matrices. This study presents the development and validation of a novel high-performance liquid chromatography coupled to a tandem mass spectrometer (HPLC-MS/MS) method for the accurate determination of USC-PFAS (carbon chain length from one to four, C1-C4) in tomato-based products (i.e. concentrate, puree, and pulp), that, due to their high water content, are prone to USC-PFAS contamination. Leveraging a polar analytical column and a delay column, the method effectively mitigates system-related interferences, especially for trifluoroacetic acid (TFA) and achieves enhanced retention and sensitivity. Target compounds included Difluoroacetic acid (DFA), TFA, Perfluoropropanoic acid (PFPrA), Perfluorobutanoic acid (PFBA), Perfluoromethanesulfonic acid (PFMeS), Perfluoroethanesulfonic acid (PFEtS), Perfluoropropanesulfonic acid (PFPrS), and Perfluorobutanesulfonic acid (PFBS). The quantification based on isotope dilution ensures high accuracy and precision. The method demonstrated excellent linearity (R² ≥ 0.99), recoveries within 65-135 %, and low relative standard deviation (RSD) values (<10 %). PFBA was detected across all tested tomato products, with concentrations ranging from 0.056 to 0.265 µg/kg, indicating potential endogenous contamination potentially linked to processing concentration effects. This study fills a critical methodological gap, offering a robust analytical tool for USC-PFAS monitoring in complex food matrices, and supporting improved food safety regulation.
More Related Videos
07:06Investigating Long-Distance Transport of Perfluoroalkyl Acids in Wheat via a Split-Root Exposure Technique
Published on: September 28, 2022
08:43PTR-ToF-MS Coupled with an Automated Sampling System and Tailored Data Analysis for Food Studies: Bioprocess Monitoring, Screening and Nose-space Analysis
Published on: May 11, 2017
Related Concept Videos
Supercritical Fluid Chromatography
SFC utilizes a supercritical fluid mobile phase,...
Thin-Layer Chromatography (TLC): Overview
To begin the analysis, a mixture of compounds is spotted on the starting line on the TLC plate using a thin capillary. The bottom of the...
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process: