An Intramedullary Locking Nail for Standardized Fixation of Femur Osteotomies to Analyze Normal and Defective Bone Healing in Mice
Published on: November 13, 2016
Comparison of compressive forces generated by dynamic compression angle-stable interlocking nail versus traditional
Caio Afonso Santos Malta1, Alefe Luiz Caliani Carrera1, Thiago André Salvitti Sá Rocha2
1Department of Clinical and Veterinary Surgery, School of Agricultural and Veterinary Sciences, "Júlio de Mesquita Filho" São Paulo State University - UNESP, Jaboticabal, State of São Paulo, Brazil.
None:
The aim of this study was to compare the compressive forces generated by Dynamic Compression Angle-Stable Interlocking Nail (DCASIN) with those of traditional Dynamic Compression Plates (DCP) and Locking Compression Plates (LCP) using synthetic diaphyseal bone models (SDBM). Three groups were established based on the fixation method (G-DCASIN, G-DCP, and G-LCP), with implants fixed to SDBM simulating a transverse fracture, comprising 10 repetitions per group. A strain-gauge load cell was positioned in the SDBM gap to measure compressive forces in kilograms, recorded 30 s after the completion of each group-specific compression technique. For G-DCASIN, the proximal SDBM was compressed against the load cell using the external implantation guide and compression device. For G-DCP and G-LCP, the same-side double loading technique was applied to the proximal SDBM. Compressive forces among groups were compared using the Kruskal-Wallis test followed by Dunn's post-hoc analysis. The mean compressive forces recorded for G-DCASIN, G-DCP, and G-LCP were 22.56 ± 5.1 kg, 27.28 ± 1.86 kg, and 11.65 ± 1.69 kg, respectively. Both G-DCASIN and G-DCP exhibited significantly greater compressive forces compared to G-LCP (p = 0.0013 and p < 0.0001, respectively), whereas G-DCASIN and G-DCP did not differ significantly (p = 0.2228). In this mechanical trial, DCASIN demonstrated the ability to generate interfragmentary compression superior to LCP and comparable to DCP. The combination of compressive capability and angle-stable locking suggests that this model may be a viable option for the treatment of transverse fractures of long bones.
More Related Videos
Related Concept Videos
Frictional Forces on Screws
A jack with a square-threaded screw is a mechanical device used to lift heavy loads by applying a force at its handle. When the force is applied, the screw turns, raising the load. The screw can...
Machines: Problem Solving I
The toggle clamp system is a machine structure consisting of movable, pin-connected multi-force members that form a stabilized system to transmit forces. The...
Behavior of Concrete Under Compressive Load
As the concrete specimen fractures under...
Wedges
Consider using a wedge to lift a heavy slab. Here, the wedge functions by converting the applied force into a much larger force directed almost perpendicular to the initial force. This...
Wood Fasteners
Nails are the most common fasteners, consisting of sharp-pointed metal pins that are driven into wood using a hammer or a mechanical nail gun. They come in a variety of diameters, heads, and lengths. Nailing techniques include...
Self-Locking Screw
A square-threaded screw jack carrying a load is considered self-locking if the screw retains its position even after the moment applied to it is removed.