Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation01:26

Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation

667
Inductively coupled plasma (ICP) is the common plasma source used in atomic emission spectroscopy (AES), a technique that detects and analyzes various elements in a sample. This method is often called inductively coupled plasma atomic emission spectroscopy (ICP-AES).
There are three main types of inductively coupled plasma atomic emission spectroscopy  (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
667
IR Spectrometers01:25

IR Spectrometers

2.4K
There are two main infrared (IR) spectrophotometers: dispersive IR spectrometers and Fourier transform infrared (FTIR) spectrometers. In a dispersive IR spectrometer, a beam of infrared radiation produced by a hot wire is divided into two parallel equal-intensity beams using mirrors. One beam passes through the sample, while another is a reference beam. The beams then move through the monochromator, which separates the radiations into a continuous spectrum of different frequencies. The...
2.4K
UV–Vis Spectrometers01:14

UV–Vis Spectrometers

3.4K
The absorbance of UV and visible (UV–visible) radiations is measured using a UV–visible spectrophotometer. Deuterium lamps, which emit UV radiation, and tungsten lamps, which produce radiation in the visible region, are used as light sources in UV–visible spectrophotometers. A monochromator or prism is used for diffraction grating, i.e., to split the incoming radiation into different wavelengths. A system of slits is used to focus the desired wavelength on the sample cell.
3.4K
UV–Vis Spectroscopy: Molecular Electronic Transitions01:16

UV–Vis Spectroscopy: Molecular Electronic Transitions

2.7K
In Ultraviolet–Visible (UV–Vis) spectroscopy, the absorption of electromagnetic radiation is used to probe the electronic structure of molecules. This technique provides insights into molecular electronic transitions, particularly the movement of electrons between different molecular orbitals. Radiation is absorbed if the energy of the electromagnetic radiation passing through the molecule is precisely equal to the energy difference between the excited and ground states. During this...
2.7K
Infrared (IR) Spectroscopy: Overview01:09

Infrared (IR) Spectroscopy: Overview

4.7K
When electromagnetic radiation passes through a material, atoms or molecules transition from a lower to a higher energy state by absorbing radiation corresponding to the energy difference between the two states. The absorption of infrared (IR) radiation causes transitions between vibrational energy levels in a molecule. Therefore, IR spectroscopy is a useful analytical tool for determining the molecular structure of molecules.
Different compounds display unique properties due to their...
4.7K
Ultraviolet and Visible (UV–Vis) Spectroscopy: Overview01:02

Ultraviolet and Visible (UV–Vis) Spectroscopy: Overview

4.5K
Ultraviolet–visible (UV–visible or UV–Vis) spectroscopy is an analytical technique that investigates the interaction between matter and UV–Vis light within the electromagnetic spectrum. This method is widely used for its versatility, simplicity, and relatively quick data acquisition, making it valuable for both qualitative and quantitative analysis. When UV–Vis radiation passes through a material,  molecules absorb light depending on the energy required for...
4.5K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

High-Performance CH-Series Non-Fullerene Acceptors for Organic Photovoltaics.

Accounts of chemical research·2026
Same author

Precise Structure Regulation Induced Morphological Ordering Enables All-Polymer Solar Cells With 20.29% Efficiency and Extreme Mechanical Robustness.

Angewandte Chemie (International ed. in English)·2026
Same author

Asymmetric π-Bridge Strategy Enables High-Sensitivity Flexible NIR Organic Photodetectors for In Situ Ultra-Trace Water Pollutant Detection.

Small (Weinheim an der Bergstrasse, Germany)·2026
Same author

Molecular interfaces drive vertical crystallization in Dion-Jacobson perovskite solar cells.

Science advances·2026
Same author

Solution-processed photovoltaic and thermoelectric hybrid systems with efficiency exceeding 50.

Nature communications·2026
Same author

Automated segmentation and quantitative analysis of vascular curvature features in unruptured intracranial aneurysms based on time-of-flight magnetic resonance angiography (TOF-MRA).

Quantitative imaging in medicine and surgery·2026

Related Experiment Video

Updated: Jan 18, 2026

High Speed Sub-GHz Spectrometer for Brillouin Scattering Analysis
13:31

High Speed Sub-GHz Spectrometer for Brillouin Scattering Analysis

Published on: December 22, 2015

15.7K

Gbits/s-Level Encrypted Spectral Wireless Communication Enabled by High-Performance Flexible Organic

Hao Qin1, Hanzhe Shi1, Tingting Guo1

  • 1The Centre of Nanoscale Science and Technology and Key Laboratory of Functional Polymer Materials, Institute of Polymer Chemistry, Renewable Energy Conversion and Storage Center (RECAST), College of Chemistry, Nankai University, Tianjin, 300071, China.

Advanced Materials (Deerfield Beach, Fla.)
|September 8, 2025
PubMed
Summary

A new organic hyperspectrometer enables high-speed wireless communication (SWC) with hardware-level encryption. This breakthrough offers secure, ultra-fast data transmission for future AI-driven networks.

Keywords:
flexible organic spectrometershyperspectrometersorganic photodetectorsspectral wireless communication

More Related Videos

High-speed Continuous-wave Stimulated Brillouin Scattering Spectrometer for Material Analysis
07:55

High-speed Continuous-wave Stimulated Brillouin Scattering Spectrometer for Material Analysis

Published on: September 22, 2017

10.6K
Quasi-light Storage for Optical Data Packets
07:45

Quasi-light Storage for Optical Data Packets

Published on: February 6, 2014

11.3K

Related Experiment Videos

Last Updated: Jan 18, 2026

High Speed Sub-GHz Spectrometer for Brillouin Scattering Analysis
13:31

High Speed Sub-GHz Spectrometer for Brillouin Scattering Analysis

Published on: December 22, 2015

15.7K
High-speed Continuous-wave Stimulated Brillouin Scattering Spectrometer for Material Analysis
07:55

High-speed Continuous-wave Stimulated Brillouin Scattering Spectrometer for Material Analysis

Published on: September 22, 2017

10.6K
Quasi-light Storage for Optical Data Packets
07:45

Quasi-light Storage for Optical Data Packets

Published on: February 6, 2014

11.3K

Area of Science:

  • Optoelectronics
  • Optical Communications
  • Materials Science

Background:

  • Conventional optical communication faces limitations in spectral efficiency, data rates, and security.
  • The exponential growth of data necessitates advanced communication technologies.

Purpose of the Study:

  • To propose a transformative high-speed organic spectral wireless communication (SWC) technology.
  • To integrate ultrahigh-speed data transmission with hardware-level encryption using a novel organic hyperspectrometer.

Main Methods:

  • Development of a flexible, miniaturized organic hyperspectrometer.
  • Synergistic combination of organic photodetector arrays with tunable responsivities and spectral-tunable organic filters.
  • Implementation of hardware-level data decoding for encrypted signals.

Main Results:

  • Achieved a broad spectral detection range (400-900 nm) with high resolution (1.08 nm) and accuracy (0.60 nm).
  • Demonstrated a rapid response time of 684 ns.
  • Attained a theoretical data rate of 9.1 Gbits/s, the highest for organic optical communication.
  • Enabled hardware-level decoding of high-speed encrypted data.

Conclusions:

  • The organic hyperspectrometer-based SWC platform represents a breakthrough in secure, high-speed, high-capacity communication.
  • Organic SWC offers unparalleled portability, adaptability, and scalability for terahertz-scale data transmission.
  • This technology is pivotal for future data- and AI-driven optical networks.