Related Experiment Video
Updated: Jan 18, 2026

Quantifying Glomerular Permeability of Fluorescent Macromolecules Using 2-Photon Microscopy in Munich Wistar Rats
Published on: April 17, 2013
Quantification of Albumin and γ-Globulin Concentrations in an Electrolyte Solution by Multivariate-Regressive
Arbariyanto Mahmud Wicaksono1, Songshi Li1, Ryoma Ogawa1
1Department of Mechanical Engineering, Graduate School of Engineering, Chiba University, Chiba 263-8522, Japan.
Abstract:
Albumin and γ-globulin concentrations in an electrolyte solution have been quantified by a multivariate-regressive Gaussian admittance relaxation times distribution (mgARTD). The mgARTD is built based on the training data consisting of the impedance spectroscopy system measurement result of protein mixture solutions with a known concentration of albumin, γ-globulin, and sodium electrolyte to perform concentration quantification on a prospective protein mixture solution with an unknown concentration. The mgARTD consists of three steps: (1) Prediction step of the peak matrix P* by Gaussian ARTD (gARTD) with the Gaussian process and peak detection algorithm, (2) Training step of the approximated coefficient matrix à based on the multivariate-regressive formula P* = Ac + φ (A: multivariate-regression coefficient matrix, φ: error matrix, and c: known concentration matrix of the training data set), and (3) Quantification step of the approximated concentration c̃ based on the Gauss-Newton algorithm from the predicted of the quantification data and the approximated Ã. In the experiments, first, à is approximated on the predicted P* and the known c under the 27 cases of protein and electrolyte concentrations (albumin: 0.800-2.400 g/dL, γ-globulin: 0.400-1.200 g/dL, and sodium electrolyte: 0.700-0.750 g/dL). Next, c̃ is determined by à and quantification data under an unknown albumin, γ-globulin, and sodium electrolyte concentration. The effect of albumin and γ-globulin on ARTD is observed in > 0.05 ms for counterion effects and in 10 μs > > 1 μs for protein reorientations. The gARTD γ* function achieves a transform fitting error of 10.90% on average, which is 12.12% lower than that of ARTD and minimizes the quantification error. The absolute percentage quantification error of c̃ by mgARTD is 9.90%, 9.12%, and 1.70% for albumin, globulin, and sodium electrolyte, respectively, which is significantly lower than 25.56%, 20.90%, and 25.71% for albumin, globulin, and sodium electrolyte by mARTD.
Related Concept Videos
Determination of Multiple Dosing Parameters: Steady-State, Minimum and Maximum Concentrations
One-Compartment Open Model: Wagner-Nelson and Loo Riegelman Method for ka Estimation
On...
Noncompartmental Analysis: Mean Transit, Absorption and Dissolution Time
One of the key parameters is the mean transit time (MTT), which refers to the total duration required for drug molecules to transit through the body. MTT is determined by calculating the ratio of the area under the moment curve to the area...
Estimation of k and VD of Aminoglycosides
Drug Distribution: Plasma Protein Binding
Complexometric EDTA Titration Curves

