Related Experiment Video
Updated: Jan 18, 2026

07:25
An Objective and Child-friendly Assessment of Arm Function by Using a 3-D Sensor
Published on: February 12, 2018
7.2K
Development and Application of the WFS-175: A Novel Multidimensional Score for Wrist Function
Sang Anh Nguyen1, Doanh Quoc Tran1
1Institute of Orthopedics and Traumatology, Military Hospital 175, Ho Chi Minh City, Vietnam.
Journal of Hand Surgery Global Online
|September 8, 2025
Summary
A new Wrist Function Score - 175 (WFS-175) protocol combines objective and subjective measures for comprehensive wrist function assessment. This digital system tracks recovery and aids clinical decisions in rehabilitation.
Area of Science:
- Orthopedics
- Rehabilitation Medicine
- Biomedical Engineering
Background:
- Standardized wrist function assessment is crucial for effective rehabilitation and clinical decision-making.
- Existing methods may lack integration of objective and subjective patient data.
- Digital tools can enhance efficiency and accuracy in patient monitoring.
Purpose of the Study:
- To introduce a novel, digital protocol for wrist function assessment.
- To develop the Wrist Function Score - 175 (WFS-175), integrating objective and subjective measures.
- To create a system for precise, longitudinal tracking of wrist function recovery.
Main Methods:
- A protocol involving data collection (range of motion, grip strength, subjective questionnaires) was established.
- Objective and subjective data were standardized onto a unified scoring scale for the WFS-175 (max 175 points).
- An AppSheet/Google Sheets system was utilized for automated calculation, storage, reporting, and visualization.
Main Results:
- A standardized assessment form and precise WFS-175 calculation were achieved.
- The protocol integrates muscular endurance and recovery measures, digitalizing the workflow.
- Initial applications demonstrated effective evaluation and tracking of wrist function recovery.
Conclusions:
- The WFS-175 protocol provides a novel, digital solution for standardized wrist function assessment.
- Combining objective and subjective measures enhances assessment sensitivity.
- This system supports clinical decision-making in modern rehabilitation.
Related Concept Videos
Assessment of apical radial pulse
1.2K
Apical-Radial (A-R) Pulse Assessment
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
1.2K
Assessment of radial pulse
1.4K
Assessment of Radial Pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
1.4K