Related Experiment Video
Updated: Jan 18, 2026

An Objective and Child-friendly Assessment of Arm Function by Using a 3-D Sensor
Published on: February 12, 2018
Development and Application of the WFS-175: A Novel Multidimensional Score for Wrist Function
Sang Anh Nguyen1, Doanh Quoc Tran1
1Institute of Orthopedics and Traumatology, Military Hospital 175, Ho Chi Minh City, Vietnam.
Purpose:
We present a novel protocol for wrist function assessment that integrates both objective factors (range of motion and grip strength) and subjective domains (pain, motor function, and quality of life) into the composite Wrist Function Score - 175 (WFS-175) score.
Methods:
The protocol consists of three main steps: (1) data collection, which involves measuring the wrist range of motion in six directions using a goniometer and grip strength, including maximum strength, endurance, and recovery, using a Jamar dynamometer, alongside concurrent subjective assessment with a standardized questionnaire; (2) standardization of all data onto a unified scoring scale, applying a linear formula to calculate the total WFS-175 score (maximum 175 points), with the following components: range of motion (30 points), grip strength (40 points), pain (25 points), motor function (40 points), and quality of life (40 points); and (3) input of results into the AppSheet/Google Sheets system, which provides automated calculation, storage, reporting, and graphical visualization for longitudinal tracking of functional recovery.
Results:
This protocol yields a standardized assessment form that enables precise calculation of the WFS-175 score. It integrates muscular endurance and recovery measures and fully digitalizes the workflow.
Conclusions:
Initial applications show that the WFS-175 score effectively evaluates wrist function and tracks recovery over time. For example, a postoperative patient scored 164/175, indicating excellent recovery.
Clinical Relevance:
The WFS-175 protocol offers a novel and digital-ready solution for standardized wrist function assessment. By combining objective and subjective measures in one scoring system, it enhances sensitivity and supports clinical decision making in modern rehabilitation.
Related Concept Videos
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:

